36
Fig. 13 Vertical twin flue system 2” (Ø 50,8 mm) with terminal
bend CPVC for pitched roof
Max length
28 + 28 ft (8.53 + 8.53 m)
90° bend
5 ft (1.52m)
the expressed lengths are without the terminations
Vertical twin flue system 2” (Ø 50,8 mm) with terminal bend PP
for pitched roof
Max length
28 + 28 ft (8.53 + 8.53 m)
90° bend
5 ft (1.52m)
the expressed lengths are without the terminations
fig. 13
Fig. 14 Vertical twin flue system 2” (Ø 50,8 mm) with terminal
bend CPVC for flat roof
Max length
28 + 28 ft (8.53 + 8.53 m)
90° bend
5 ft (1.52m)
the expressed lengths are without the terminations
fig. 14
Fig. 15 Horizontal twin flue system 3” (Ø 76,2 mm) with
terminal bend CPVC
Max length
76+76 ft (23.16+23.16 m)
90° bend
6 ft (1.83m)
the expressed lengths are without the terminations
fig. 15
increaser 2”-3”
Fig. 16 Twin flue system 3” (Ø 76,2 mm) with horizontal
terminal 3” (Ø 76,2 mm) CPVC
Max length (L)
76+76 ft (23.16+23.16 m)
Terminal length (L1)
part no 197009
1.67 ft (0.5 m)
part no 197107
2.67 ft (0.8 m)
part no 197117
3.67 ft (1.1 m)
fig. 16
increaser 2”-3”
Summary of Contents for Family PRO 42 IS
Page 75: ...75 ...