background image

6

ADJUSTING THE GAS VALVE

 

- Turn the function selector to OFF/RESET (the display 

shows “- -”)

 

- Pull off all 3 control knobs (DHW temperature, function 

selector and CH temperature).

 

- Unscrew the four screws (A) and remove the front trim 

(B).

 

- Press the combustion analysis button (CO).

 

- Wait for the burner to ignite. The display will read out 

“CO” and the boiler will start functioning at maximum 
central heating power. The chimney sweep function 
remains active for a maximum time of 15 minutes. If the 
central heating flow reaches a temperature of 95°C, the 
burner shuts down. The burner will re-ignite when cen-
tral heating flow temperature drops below 75°C. 

 

- Remove the cap and insert the combustion analysis 

probe. 

 

- Turn the HTG trimmer clockwise until maximum fan 

speed is reached (see table). 

 

- Check the CO

2

 content. If the value is not as speci-

fied in the table, adjust the gas valve maximum screw 
accordingly. 

 

- Turn the HTG trimmer anticlockwise until minimum 

speed is reached (see table). 

 

- Check the CO

2

 content. If the value is not as specified 

in the table, adjust the gas valve minimum screw accor-
dingly. 

 

- Return the HTG trimmer to the correct Max CH setting 

(see table). 

 

- Turn the function selector to exit chimney sweep mode. 

 

- Remove the combustion analysis probe and replace 

the cap. 

 

- Fit the front trim (B) and secure with the four screws (A).

 

- Push the 3 control knobs back on to their pins in the 

front trim.

The combustion analysis function stops automatically if 
the control card detects an error condition. If an error 
occurs during combustion analysis, proceed as follows 
to perform a reset. Turn the function selector to “

}

”, and 

then to “

{

”, and then to the desired function. 

Labels  

 

- Remove the G20 label from the outside of the boiler 

casing. 

 

- Apply the G31 label to the inside of the casing, covering 

the old G20 label.

MAXIMUM FAN SPEED

METHANE (G20)

PROPANE (G31)

12 ISCN

51

51

rpm 

21 ISCN

55

60

rpm 

MINIMUM FAN SPEED 

METHANE (G20)

PROPANE (G31)

12 ISCN

13

17

rpm 

21 ISCN

13

13

rpm 

MAX CO

2

 VALUES

METHANE (G20)

PROPANE (G31)

12 ISCN

9,0

10,0

%

21 ISCN

9,0

10,0

%

MIN CO

2

 VALUES

METHANE (G20)

PROPANE (G31)

12 ISCN

9,0

10,0

%

21 ISCN

9,0

10,0

%

GAS SUPPLY PRESSURE:

COUNTRY OF DESTINATION:

GB

Country of destination:

Type of boiler:

Boiler category: 

II2H3P

Gas supply pressures: 

G20
G31

20 mbar
37 mbar

Manufacturer setting:

G20 - 20 mbar

IMPORTANT!

Read the instruction manual thoroughly 

before installing and starting up the boiler.

B23P, B53P, C13, C33, C43,
C63, C83, C13x, C33x,
C43x, C53x, C63x, C83x

GB

0

bar

4

1

3

2

°C

0

120

20

100

40

80

60

Max. gas

power screw 

Max. gas

power screw 

Summary of Contents for B23P

Page 1: ...ASFORMAZIONE DA UN TIPO DI GAS ALL ALTRO ITALIANO 3 cod 069305 Rev 3 08 11 CONVERSION FROM ONE GAS TYPE TO ANOTHER DEUTSCH 7 TRANSFORMATION D UN TYPE DE GAZ UN AUTRE FRAN AIS 9 UMSTELLUNG AUF ANDERE G...

Page 2: ......

Page 3: ...in avanti il pannello di comando Svitare il dado A scostare leggermente il tubo B e sostituire il diaframma contenuto al suo interno con quello contenuto nel kit Rrimontare il tutto procedendo in sens...

Page 4: ...anto riportato in tabella agire sulla vite di regolazione del min della valvola gas Riportare il trimmer HTG al numero di giri della massima potenza riscaldamento vedi tabella Per uscire dalla funzion...

Page 5: ...trol panel and tilt it forwards Unscrew the nut A Move the pipe B gently to one side and replace the diaphragm inside the pipe with the new diaphragm supplied in the kit Reverse the above steps to rea...

Page 6: ...nction selector to exit chimney sweep mode Remove the combustion analysis probe and replace the cap Fit the front trim B and secure with the four screws A Push the 3 control knobs back on to their pin...

Page 7: ...D crocher le tableau de commande et le faire pivoter vers l avant D visser l crou A carter l g rement le tuyau B et remplacer le diaphragme contenu l int rieur par le diaphragme pr sent dans le kit Re...

Page 8: ...r quitter la fonction ramonage tourner le bouton de commande Extraire la sonde d analyse des fum es et remonter le bouchon Remettre la plaque B et visser les 4 vis A Remettre en place les 3 boutons de...

Page 9: ...gsblende auf und klappen Sie diese auf L sen Sie die Mutter A heben Sie den Schlauch B leicht ab und tauschen Sie die darin enthaltene Drossel durch die im Bausatz gelieferte aus Bauen Sie die Teile a...

Page 10: ...le Heizleistung zur ck siehe Tabelle Zum Beenden der Funktion Schornsteinfeger drehen Sie den Betriebswahlschalter Nehmen Sie den F hler des Abgastesters ab und brin gen Sie den Verschluss an Bringen...

Page 11: ...k het bedieningspaneel los en draai het naar voren Draai de moer A los doe de buis B iets opzij en ver vang het diafragma erin door dat van de kit Ga voor hermontage in tegenovergestelde volgorde te w...

Page 12: ...e schoorsteenveger af door te draaien aan de bedieningsknop Verwijder de rookanalysesonde en breng de dop weer aan Draai de vier schroeven A weer vast om het frontpane eltje B te bevestigen Steek de 3...

Reviews: