25
USE
fault codes for indoor unit
Code
Display Description
Remarks
01
01.5°C
Room probe fault
The unit resets after problem
resolution
02
02.5°C
Exchanger probe fault
04
04.5°C
Microprocessor malfunction
07
07.5°C
Communication error between
indoor unit and outdoor unit
12
0C.5°C
Malfunction condensation
drain system
13
0D.5°C
Zero cross signal detected
wrong
14
0E.5°C
Fan motor malfunction
16
10.5°C
Indoor unit operating mode
different from outdoor unit
faults requiring intervention of the Technical
Support Service
If any of these faults occurs:
—
the power cable is too hot or damaged
—
a strange noise is heard during operation
—
the circuit breaker, a fuse or the circuit breaker circuit
breaker trips continuously
—
a switch or a button is not operating properly
—
user smells burnt
—
water leaks from the indoor unit
An accurate inspection of equipment components is required.
—
set the main switch to “Off”
—
immediately contact
R
Technical Support Service.
Normal noise during operation
During normal operation, the equipment may make particular
noise linked to settling, expansion of the materials or refrigerant
flow. This type of noise should not be considered a fault:
—
ticking due to expansion or shrinking of materials upon
temperature changes
—
hiss due to refrigerant cycle inversion when changing op-
erating mode and toggling between Cooling and Heating
or during defrost
—
swish similar to water flowing due to the refrigerant gas
flowing in the unit