14

USE

• 

Activation

 

press 

 appears on the display of the remote control and the unit.

Set required temperature as follows:

 

work on 

Value is stored with no need to press other buttons.

• 

Switch-off

 

select another operating mode

Alternatively:

 

press 

Dehumidification mode

Dehumidification mode allows starting and using the system to 
reduce ambient humidity.
Required ambient temperature available range is between 16 °C 
and 30 °C.
The equipment will operate at displayed ventilation speed. 
When the delta between ambient temperature ad set tempera-
ture is below two degrees, the equipment will operate intermit-
tently at the minimum ventilation speed.

• 

Activation

 

press 

 appears on the display of the remote control and the unit.

Set required temperature as follows:

 

work on 

Value is stored with no need to press other buttons.

• 

Switch-off

 

select another operating mode

Alternatively:

 

press 

 to deactivate

Smart mode

In Automatic mode, equipment automatically changes operat-
ing mode, toggling between Cooling and Heating to keep a con-
stant ambient temperature when outdoor conditions change.
Temperature settings are preset.

• 

Activation

 

press 

Remote control display shows 

.

• 

Switch-off

 

select another operating mode

Alternatively:

 

press 

 to deactivate

Adjusting ventilation speed

Ventilation speed can be adjusted in the following modes:

 

Cooling

 

Heating

 

Dehumidification

 

Ventilation

Set required ventilation speed as follows:

Summary of Contents for Aaria Mono Plus AMK P Series

Page 1: ...POWER TIMER Remote control AMW P AMW ST AMK P 06 2018 cod Doc 0083011 rev 4 EN USER INSTRUCTIONS ...

Page 2: ...o incorrect installation adjustments or maintenance or improper use Dear customer Thank you for choosing a R product an innovative and high quality appliance that guarantees wellbeing for a long time This manual contains information we deem necessary for correct and easy use Thanks again RIELLO WARRANTY R product has a Conventional Warranty valid for Italy Republic of San Marino Vatican City start...

Page 3: ...ilation speed p 14 Quiet function p 15 Maximum power function p 15 2 4 Use with open flap p 15 Horizontal motorised deflector p 15 Vertical motorised deflector p 16 Ventilation mode p 16 Sleep function p 16 Health air flow function p 17 Anti freeze function p 17 Switching unit display off or on p 18 Hourly programming p 18 Selecting the temperature measurement unit p 19 Setting the transmission co...

Page 4: ...ble object spray cans within a 1 metre radius from the air expulsion 9 According to EU Regulation no 517 2014 regarding certain fluorinated greenhouse gases the total amount of refrig erant contained within the installed system must be indi cated This information can be found on the unit technical data plate 9 This unit contains fluorinated greenhouse gases covered by the Kyoto protocol Maintenanc...

Page 5: ...l in order to control the operation of the outdoor unit and regulate the room temperature 9 Safety device replacement must be carried out by R Technical Support Service using only original components Please refer to the spare parts catalogue 0 0 IT IS FORBIDDEN to operate the device with faulty safety sys tems Identification The unit can be identified through the technical data plate 0010585659 10...

Page 6: ... de tected value to the control panel which is trigged in case of abnormal temperature with regard to the operating mode room air temperature sensor transmitting the detected value to the control panel in order to control the operation of the outdoor unit and regulate the room temperature 9 Safety device replacement must be carried out by R Technical Support Service using only original components ...

Page 7: ...Remote control 1 2 4 5 6 8 7 3 POWER TIMER Unit display The unit display shows the temperature and the alarms if any 1 Display 1 1 Temperature indication 1 1 Detected ambient temperature 2 Required temperature when using the button 3 Alarm code Light indicators The switching on of the lights indicates some states of function ing 1 Light indicators 1 ...

Page 8: ...d in case of abnormal temperature with regard to the operating mode room air temperature sensor transmitting the detected value to the control panel in order to control the operation of the outdoor unit and regulate the room temperature 9 Safety device replacement must be carried out by R Technical Support Service using only original components Please refer to the spare parts catalogue 0 0 IT IS F...

Page 9: ...densation discharge 6 Motor driven deflectors 7 Display 8 Air intake grille 9 Fresh air hole 10 Remote control 1 3 6 7 8 9 4 5 2 10 POWER TIMER Unit display The unit display shows the active functioning mode the tem perature and the alarms if any 1 Display 1 1 Timer on 2 Temperature indication alarm code 1 2 ...

Page 10: ... activates the Smart mode POWER It enables the Maximum Power function DOOR OPEN 1 Door 2 Advanced function keys FAN MODE TIMER 2 1 When the door is open you can access the advanced functions e g time scheduling and motor driven deflector settings Function keys with door open It activates and deactivates the automatic movement of the horizontal deflector or stops it in a specific position It activa...

Page 11: ...the keys WiFi connection enabled Remote control keys locked Operating mode Cooling mode enabled Heating mode enabled Dehumidification mode enabled Ventilation mode enabled Functions Sleep function enabled Not available Smart mode enabled Timer settings Timer setting value or current time display Switch on timer enabled Switch off timer enabled Motor driven deflector settings Horizontal deflector p...

Page 12: ...ch new and old batteries or different types of batteries 9 When you remove the batteries all settings in the remote control will be deleted Fit the new batteries and reprogram 9 Do not dispose of old batteries in the environment Always take them to the suitable containers at points of sale Time setting The current time must be set before using the remote control FAN MODE open the door press work o...

Page 13: ...tivate the quick functions such as choosing the operating mode and setting the desired temperature 9 Ensure that the door is fully closed If this is not the case the external keys will not work Cooling mode The Cooling mode allows starting and use of the air condition er as a producer of cold and dehumidified air To activate this function an external temperature between 10 C and 46 C is recommende...

Page 14: ... tently at the minimum ventilation speed Activation press appears on the display of the remote control and the unit Set required temperature as follows work on Value is stored with no need to press other buttons Switch off select another operating mode Alternatively press to deactivate Smart mode In Automatic mode equipment automatically changes operat ing mode toggling between Cooling and Heating...

Page 15: ...ate Maximum power function Equipment operation is forced to maximum so as to quickly achieve ambient required conditions The Maximum power function can be turned on in the following modes Heating Cooling Activation press POWER Remote control display shows Switch off select another operating mode Alternatively press to deactivate 2 4 Use with open flap When the door is open you can access the advan...

Page 16: ... The vertical motorised deflector controls the horizontal air flow by setting a preferred outlet tilt or activating automatic opera tion not available on AMW ST Set required deflector position as follows A Initial position A work on select required position Each press will select a different position If is selected the position automatically changes accord ing to predefined logics from the program...

Page 17: ... aiming the air flow directly at persons Activation press Remote control display shows This setting is recommended for Cooling mode Change deflector position as follows press Remote control display shows This setting is recommended for Heating mode Switch off press the deflector goes back to the position it had prior to function activation 9 With Health air flow function on horizontal deflector po...

Page 18: ...ctivation aim the remote control on the side opposite to unit re ceiver press The remote control turns on aim the remote control to unit receiver press The display shows the intermittent and the time previously set Set required time as follows work on Each time the key is pressed the values changes by 1 By keeping the key pressed down the value changes faster confirm with The symbol ends intermitt...

Page 19: ...t transmission channels can be set For communication to succeed the selected communication channel on indoor unit and remote control must be the same Available transmission channels are Factory set channel is A Select required channel as follows work on Each press will select a different channel toggling between A and B 9 The unit will not operate if the transmission channel settings in indoor uni...

Page 20: ... is fundamental for keeping the equip ment efficient safe and reliable It can be performed periodi cally by R Technical Support Service whose staff is technical ly qualified and can use genuine spare parts if necessary 2 9 Cleaning AMW P AMW ST The only necessary cleaning on the part of the user are those of the remote control of the cover cabinet of the front grille of the mesh filters and the re...

Page 21: ...idden to use the device without mesh filter Purifying filter replacement The cleaning of the purifying filters if present allows the opti mal operation of the air conditioner and guarantees the quality of the treated air To replace the filters 1 Mesh filters 1 open the front panel take out the mesh filter by grabbing the relevant fins 1 Mesh filters 2 Air purifying filter 2 1 remove exhausted puri...

Page 22: ...ushes Mesh filter cleaning open the air intake grill unfasten grill remove grill 1 Mesh filters take out the mesh filter by grabbing the relevant fins remove dust with an vacuum cleaner 9 Stubborn dirt can be removed by washing the filter in a luke warm max 40 C solution of water and neutral detergent After washing rinse the filters well and leave to dry in the shade 9 Exposing the filters to the ...

Page 23: ...ical Support Service AWM P Faults on unit display Operating anomalies are signaled with a code from the indoor unit display Their intervention secures the appliance and blocks its operation 1 Display 1 1 Temperature indication 2 Operating mode 1 2 2 To restore operating conditions set the main switch to Off allow 10 minutes reposition the general switch on on press on the remote control Iftheclima...

Page 24: ...changer probe fault E4 Microprocessor malfunction E7 Communication error between indoor unit and outdoor unit E14 Fan motor malfunction AMK P Faults on unit display Operating anomalies are signaled with a code from the indoor unit display Their intervention secures the appliance and blocks its operation 1 Display 1 1 Timer on 2 Temperature indication alarm code 1 2 To restore operating conditions ...

Page 25: ...g operation the circuit breaker a fuse or the circuit breaker circuit breaker trips continuously a switch or a button is not operating properly user smells burnt water leaks from the indoor unit An accurate inspection of equipment components is required set the main switch to Off immediately contact R Technical Support Service Normal noise during operation During normal operation the equipment may...

Page 26: ... disposal 3 DISPOSAL Packing materials must be disposed of separately in order to be recovered and recycled Equipment at end of life and flat bat teries must be disposed of as required by prevailing law and regulations ...

Page 27: ......

Page 28: ...l 39 0442 630111 fax 39 0442 630371 www riello it As the manufacturer is constantly improving its products the aesthetic or dimensional features the technical data the equipment and accessories indicated could be subject to variations ...

Reviews: