Input Terminals
The black test lead plugs into the negative (COM) terminal and the red test lead plug the
positive terminal. The Transformer Jaw Clamp is used for DC/AC current measurement.
Figure 7 – Input Terminals
Pushbuttons
Mode Button
The Mode Button is used to select Ohms/Diode/Continuity, DC/AC Current and Voltage,
Degrees F/C in the appropriate rotary switch settings.
1. In Current measurement function, pressing the Mode button will select the AC range
from the default DC range.
2. In Voltage/Frequency measurement function, pressing the Mode button once will
select the AC range from the default DC range. If the button is pressed for 3 seconds,
the meter will enter Frequency measurement function.
3. In Resistance/Diode/Continuity function, pressing the Mode button will change from
default Resistance function to Diode test and then Continuity test function.
4. In Temperature measurement function, pressing the Mode button will change from
default °C to °F units.
Peak Hold Button
The Peak Data Hold function records the maximum and minimum readings for current
and voltage on the display.
1. Press the Peak Hold button once to record the peak maximum value. The meter
beeps and indicator “P MAX” appears on the display.
2. Press the Peak Hold button again to record the peak minimum value. The meter
beeps and indicator “P MIN” appears on left-upper corner of the display.
3. Press the Peak Hold button for 3 seconds to deactivate.
Data Hold Button
The Data Hold function allows the meter to freeze a measurement for later reference.
1. Press the Data Hold button to freeze the reading on the
DISPLAY
. The meter beeps
and indicator “HOLD” appear on the display.
2. Press the Data Hold button to return to normal operation.
DC Zero Button
The DC Zero Button is used in case of DC current measurement to zero the clamp cur-
rent for accurate measurement.
Backlight Button
1. Press the Backlight button for 3 seconds to turn the display light ON.
2. Press Backlight button again for 3 seconds to exit the backlight mode.
micro CM-100 Digital Clamp Meter
11
Terminals
Description
V /
Input Positive Terminal for Voltage, Resistance,
Ω
/ CAP /
Continuity Test, Diode Test, Capacitance,
TEMP /Hz
Temperature and Frequency Measurement
COM
Negative Terminal for all measurements
Summary of Contents for Micro CM-100
Page 38: ...Multim tre num rique pinces micro CM 100 36...
Page 58: ...Mult metro de Mordaza Digital micro CM 100 56...
Page 98: ...micro CM 100 Digitale stroomtang 96...
Page 118: ...Misuratore digitale a pinza micro CM 100 116...
Page 138: ...Amper metro Digital CM 100 micro 136...
Page 158: ...micro CM 100 Digital t ngmultimeter 156...
Page 232: ...Cyfrowy miernik c gowy micro CM 100 230...
Page 288: ...Cle te de curent digital micro CM 100 286...
Page 308: ...micro CM 100 Digit lis lakatfog s multim ter 306...
Page 309: ...micro CM 100 micro CM 100 micro CM 100...
Page 311: ...micro CM 100 309 t t t t t...
Page 312: ...micro CM 100 310 t t t t t t t t t t t RIDGID micro CM 100...
Page 320: ...micro CM 100 318 5 micro CM 100 30 V AC RMS 42 V AC 60 V DC 600 VAC VDC 1 2 t t t t t 0 3 4 5...
Page 324: ...micro CM 100 322 3 4 5 2 3 COM V CAP TEMP Hz 4 5 6 t 0 t 0 t 2 3 COM V CAP TEMP Hz 4 5 6 35...
Page 328: ...micro CM 100 326 RIDGID...
Page 384: ...micro CM 100 digitalna strujna kle ta 382...
Page 385: ...micro CM 100 micro CM 100 micro CM 100...
Page 387: ...micro CM 100 385 t t t t t...
Page 388: ...micro CM 100 386 t t t t t t t y e t t t t...
Page 396: ...micro CM 100 394 5 1 2 3 9 NEDA 1604 IEC 6F22 6LR61 4 1 2 3 t t t t 4 t t 5...
Page 397: ...micro CM 100 395 micro CM 100 30 42 60 DC 600 1 2 t t t t t OFF 3 4 5...
Page 398: ...micro CM 100 396 6 OL 7 OFF 20 1000 400 40 C F COM V CAP TEMP Hz COM 7 6...
Page 400: ...micro CM 100 398 1 2 3 COM V CAP TEMP Hz 4 0 5 DC AC V 8 1 2 3 4...
Page 401: ...micro CM 100 399 5 1 2 COM V CAP TEMP Hz 3 4 5 1 2 3 COM V CAP TEMP Hz 4 5 6 t OL t 0 o t o...
Page 403: ...micro CM 100 401 9 3 4 30 5 6 C F t t RIDGID RIDGID micro CM 100 44748 44758 K...
Page 405: ...micro CM 100 403 RIDGID...
Page 406: ...micro CM 100 404...
Page 427: ......