T
echnical
B
ulletin
PAGE: 4/5
Reissued: 10-May-11
Model:
Al-P1
Date:
13-Mar-08
No
.: RG179002i
Version
Modified Points or Symptom Corrected
2. After a job consisting of a multiple of exactly 8KB (8192 bytes) is submitted via
IPP, the device will no longer accept any more jobs until rebooted.
3. If both SNTP and Date/Time settings are configured in WIM, WIM might not be
accessible. This happened very infrequently (about 1% of the time).
Note: The fix requires that System firmware version 1.11 or later be applied to the
device.
7.20
1. If the device fails to establish a WPA or WPA2 connection once, it will not try
again until rebooted.
2. The device is unable to roam between access points using different versions of
the IEEE 802.11 standard (a, b, or g).
3. LPR jobs submitted by an HP-UX, AIX or Netware 6.5 (SP6 or SP7) host will be
cancelled, resulting in an error.
Note: This problem will not affect Netware 6.5 SP7 if the patch
"iprntnw65sp7b.zip" has been installed.
http://download.novell.com/Download?buildid=HsQQ9fMHax0~
4. The device doesn't advertise its hostname via DHCP option 12. The DNS server
might not be updated by DHCP.
7.17 Symptom
corrected:
1. Jobs submitted using the IE ftp client result in an SC991 error. This only occurs
using Windows XP x64.
2. Sending a PJL readback (or ustatus) will result in an SC997. This only occurs if
diprint's bidirect is on from telnet.
3. SNMP events (Access Violation or Lockout), are not recorded in the Access Log.
4. If the sending of a Scan to Email using SMIME is interrupted (Ie. A job is
submitted to the printer or the device application is switched before the email has
been sent), an SC997 error will occur.
5. When a WSD client boots, the device's WSD service might be stopped.
6. "Date/Time" changes initiated by an SNTP server are not recorded in the Access
Log.
The device might not be able to access the network once the Log collection tool is
run (TechMail#TS080441).
7.14
Symptom corrected:
1. The device might not be able to reboot via WIM after the device's date/time is
decremented to an earlier date/time using WIM.
2. An SSL2.0 client code fails to properly check for NULL(CVE-2006-4343).
(TechMail#OTS-2008-185)
3. Multiple RSA implementations fail to properly handle signatures(CVE-2006-4339).
(TechMail#OTS-2008-276).
4. Web SmartDeviceMonitor shows the IP addresses of TWAIN clients in reverse.
Example
:
192.168.1.10 ==> 10.1.168.192
5. If an LPR job is submited to the device followed by an AppleTalk job, the device
will stall.
6. An SC819 error might be shown on the operation panel if the device is accessed
via IPsec repeatedly without a power cycle.
7. An SC997 will be displayed on the Operation Panel of EFI controller based
devices if IPv6 network settings are changed.
8. Excessive time lag when the device rejoins the network after exiting Energy
Saver Mode. This will occur under either one of the following conditions:
-
The device is connected to a hub that uses the spanning tree protocol.