T
echnical
B
ulletin
PAGE: 5/5
Model:
AL-P1
Date:
21-Dec-09
No.:
RG179015
IV.
Set the following SP modes to the values shown.
SP
Mode:
Set
to
this
value:
SP 2201-01
(Development Bias):
560(default)
SP 2201-02
(Development Bias for ID sensor pattern):
400(default)
Note:
For high-CV users (APV: 30K or more), set this SP to a value of
460
.
SP 2001-01
(Charge Roller Bias):
1500(default)