5. Troubleshooting
LED Display
LED Display (Problems are shown by a combination of LED Indicators)
Status of Indicator Lights
Trouble
Cause
Solution
Standby power is
not on.
There is a problem with
the power supply or the
main board.
Check the power
supply.
Check the connector.
Check the main board.
Lamp error
Lamp went out
during use, or
won't come on.
• Lifetime of the lamp
has ended.
• The rotation of the
color wheel is not
detected.
• The lamp ballast is
defective.
• The temperature
around the lamp
ballast is high.
• Replace the lamp.
• Clean the inside of
the projector.
• Replace the optics
section.
• Replace the lamp
ballast.
(Flashes at 2-second
intervals)
Lamp off error
The projector failed
to switch off the
lamp.
• The processor in the
lamp ballast is
malfunctioning.
• The main processor
is malfunctioning.
Disconnect the power
cord, and then connect
it again.
(Flashes at 1-second
intervals)
Lamp cover error
Power went out
during use, or
power won't come
on.
• The lamp cover is
not properly
attached.
• The lamp cover
open sensor is
defective.
• Check if the lamp
cover is properly
attached.
• Check the lamp
cover open
sensor.
69
Summary of Contents for Soleil-PJ WX4130
Page 1: ...Model Soleil PJ1 Machine Codes Y011 Y012 Field Service Manual October 2011...
Page 2: ......
Page 8: ...6...
Page 18: ...Network board Wireless LAN module Y012 only 3 Replacement and Adjustment 16...
Page 24: ...3 Remove a screw 4 Remove a screw 5 Rear cover A x 2 3 Replacement and Adjustment 22...
Page 37: ...3 Exhaust fan A x 1 Lamp Ballast 1 PSU p 28 2 Remove a screw and a cable Parts Replacement 35...
Page 39: ...3 Exhaust duct A x 2 4 Exhaust duct A x 2 5 Cover A x 1 Parts Replacement 37...
Page 57: ...3 Press the MENU button Electrical Adjustment 55...
Page 58: ...3 Replacement and Adjustment 56...
Page 70: ...4 System Maintenance 68...
Page 82: ...MEMO 80 EN...
Page 83: ...Model Soleil PJ1 Machine Codes Y011 Y012 Appendices Dec 2011...
Page 84: ......
Page 86: ...2...
Page 99: ...MEMO 15...
Page 100: ...MEMO 16 EN...