Error
ID
Meaning
Cause
Solution
7
Temp error
• The temperature around
the intake fan is 42
degrees C or higher.
• Temperature sensor is
defective.
• Check the environment, e.g.
whether there is any heat
source near the projector.
• Check if the temperature sensor
connector (CN10) is properly
connected.
• Replace the temperature sensor
board.
• Replace the main board.
8
Installation error
The projector is tilted at angle of
30 degrees or more.
• Check the projector condition.
• Check if the control panel
connector is properly
connected.
9
Memory read
error
A data access error occurred
while accessing the EEPROM
on the main board.
Replace the main board.
10
Audio processor
error
A data access error occurred
while accessing the audio
device.
Replace the main board.
11
Video processor
error
A data access error occurred
while accessing the video
decoder.
Replace the main board.
12
A/D converter
error
A data access error occurred
while accessing the A/D
converter.
Replace the main board.
13
HDMI receiver
error
A data access error occurred
while accessing the HDMI
receiver.
Replace the main board.
Error ID
73
Summary of Contents for Soleil-PJ WX4130
Page 1: ...Model Soleil PJ1 Machine Codes Y011 Y012 Field Service Manual October 2011...
Page 2: ......
Page 8: ...6...
Page 18: ...Network board Wireless LAN module Y012 only 3 Replacement and Adjustment 16...
Page 24: ...3 Remove a screw 4 Remove a screw 5 Rear cover A x 2 3 Replacement and Adjustment 22...
Page 37: ...3 Exhaust fan A x 1 Lamp Ballast 1 PSU p 28 2 Remove a screw and a cable Parts Replacement 35...
Page 39: ...3 Exhaust duct A x 2 4 Exhaust duct A x 2 5 Cover A x 1 Parts Replacement 37...
Page 57: ...3 Press the MENU button Electrical Adjustment 55...
Page 58: ...3 Replacement and Adjustment 56...
Page 70: ...4 System Maintenance 68...
Page 82: ...MEMO 80 EN...
Page 83: ...Model Soleil PJ1 Machine Codes Y011 Y012 Appendices Dec 2011...
Page 84: ......
Page 86: ...2...
Page 99: ...MEMO 15...
Page 100: ...MEMO 16 EN...