9. Remove the mag-
net adjustment
plate [G] and the
development roller
adjustment gear
[H] (2 screws, 1
spacer, 1 E ring, 1
bushing).
10. Remove the back-
spill plates [I] (1
screw).
11. Remove the mixing
auger [J] and the
mixing separator
casing [K] (4
screws).
12. Peel off the side
seal and pull out
the development
roller.
13. After replacing the development roller, put the side seal at the same
location on the new roller.
14. Adjust the doctor gap and the photoconductor gap.