5.4 ID SENSOR VOLTAGE ADJUSTMENT
ADJUSTMENT STANDARD: 4
±
0.1V
1. Turn off the main
switch and take off
the middle right
cover. (Loosen 4
screws.)
2. Turn on the main
board DIP switch
101-8.
3. Turn on the main
switch.
4. Attach the multime-
ter leads to TP102
(Vsg OUT) and
TP106 (GND).
5. Press the Lighter
key to manually set
the image density
at level 2 and set
Lead Edge Erase
at 10 mm.
6. Press the Copy Exit
Way key. (This
turns on the ID sen-
sor LED.)
7. Turn VR104 to ad-
just Vsg to 4
±
0.1
volts.
6 January 1990