80012F(H) - ID code (low - Hex)
800130(H) - ID code (high - Hex)
800131(H) - Confidential ID (low - BCD)
800132(H) - Confidential ID (high - BCD)
800133(H) - Memory lock ID (low - Hex)
800134(H) - Memory lock ID (high - Hex)
800140 to 800146(H) - Last power off time (Read only)
800140(H) - Year (BCD)
800141(H) - Month (BCD)
800142(H) - Day (BCD)
800143(H) - 00: Monday, 01: Tuesday, 02: Wednesday, ....... , 06: Sunday
800144(H) - Hour
800145(H) - Minute
800146(H) - Second
* 800150(H) - Optional equipment (Read only)
Bit 0: Memory card
0: Not installed, 1: Installed
Bit 1-3: Not used
Bit 4: 100 sheet cassette
0: Not installed, 1: Installed
Bit 5: Paper feed unit
0: Not installed, 1: Installed
Bit 6-7: Not used
800151(H) - Optional equipment (Read only)
Bit 0: Not used
Bit 1: Printer interface
0: Not installed, 1: Installed
Bit 2-7: Not used
The following counters are listed on the System Parameter List. The names used on the sys-
tem parameter list are given in brackets.
800158 to 80015A(H) - Tx counter (TX)
Address
High
Low
800158(H)
Tens digit
Unit digit
800159(H)
Thousands digit
Hundrets digit
80015A(H)
Millions digit
Ten thousands digit
Note: The following counters have the same data format as above.
80015B to 80015D(H) - Rx counter (RX)
80015E to 800160(H) - Scan counter (SCN)
800161 to 800163(H) - Print counter (PRT)
800164 to 800166(H) - Printer interface output counter (PRN)
800167 to 800169(H) - Paper feed counter: standard cassette (UPPER CASSETTE)
* 80016A to 80016C(H) - Paper feed counter: optional PFU (CASSETTE 2)
80016D to 80016F(H) - Paper feed counter: optional 100 sheet cassette (OPEN CASSETTE)
800170 to 800172(H) - Paper feed counter: bypass feed (BY-PASS)
800173 to 800175(H) - ADF counter (ADF)
August 2nd, 1995
SERVICE TABLES AND PROCEDURES
SERVICE RAM ADDRESSES