Step
Item
Procedure
6
Scan line
1. Access the SBU as explained in
“Preparation” above.
2. Set the oscilloscope scale to 0.2
V/unit (vertical) and 0.5 ms/unit
(horizontal).
3. Connect the oscilloscope probe to
XVIDEO (pin 1 - blue wire) and the
ground to GND (pin 4 - black wire)
on the test lead.
4. Light the xenon lamp (see page 2-
24).
5. Place the scan line test chart [A] on
the exposure glass as shown.
6. Loosen the SBU securing screws
(see procedure 1).
7. Adjust the waveform with the adjust-
ing knobs until the waveform is as
shown on the right.
3-18
Summary of Contents for FACSIMILE FAX77
Page 1: ...RICOH FACSIMILE RICOH FAX77 80 85 FIELD SERVICE MANUAL...
Page 5: ...SECTION 1 INSTALLATION...
Page 20: ...1 3 2 Minimum Space Requirements 1 14...
Page 23: ...1 5 Installation Procedure 1 Attach the copy tray 1 2 Attach the document tray 2 1 17...
Page 30: ...SECTION 2 PROGRAMMING TESTING...
Page 32: ...2 1 Operation Panel FAX77 2 1...
Page 33: ...2 2...
Page 103: ...SECTION 3...
Page 135: ...SECTION 4...
Page 139: ...Jumpers 6 and 7 1 J P 6 J P 7 3 J P 6 J P 7 4 3...
Page 141: ...SECTION 5...
Page 169: ...Rx Motor FWD STOP REV Cutter ON Motor OFF Rx Motor ON Cutter Motor OFF 5 27...
Page 170: ...SECTION 6 RICOH MEMORY OPTION TYPE 85...
Page 173: ...ELECTRICAL DATA...
Page 175: ...7 1 Point to point Diagram...
Page 183: ...7 3 Block Diagrams 7 9...
Page 184: ...2 Video Data Path Transmission...
Page 185: ...Reception 7 11...
Page 186: ...7 12...
Page 187: ...3 Power Distribution 7 13...
Page 188: ...4 Scanner Drive 7 14...
Page 189: ...5 Printer Drive 7 15...
Page 190: ...7 4 Electrical Component Layout 7 16...
Page 192: ...APPENDIX...
Page 193: ...APPENDIX A GLOSSARY...