• On the fan fold unit, check that the main switch [1] and heater switch [2] are off.
1. Connect the fan fold unit power cord to the power source.
2. Look at the circuit breaker [3].
• With the horizontal line displayed on the circuit breaker, use the tip of a small screwdriver to
depress the breaker test button.
• The circuit breaker should flip to the "O" position. This indicates that the circuit breaker is operating
normally.
• If the circuit breaker does not flip to the "O" position, the circuit breaker must be replaced.
• Push the lever to display the vertical line again and reset the machine for normal operation.
• The fan fold unit will not switch on if the lever remains at the "O" position.
3. Disconnect the fan fold unit power cord from the power source.
Power On
The fan fold unit must be switched on before the main machine.
1. Switch on the fan fold unit.
2. Switch on the main machine.
• The fan fold unit must be switched on first, so that the main machine will recognize the fan fold unit
after the main machine is powered on and starts its initialization procedure.
Skew Adjustment
1. After setting up the system, do a folding test run with at least 10 sheets of A1 LEF paper.
• Before doing this procedure, measure the distances between the bridge unit and the left and
right rear corners of the main machine. The difference between these two distances must not be
more than 1 mm.
2. Measure the amount of skew.
• If the average amount of skew is less than ±0.5 mm, no adjustment is required.
• If the average amount of skew is more than ±0.5 mm, adjustment is required.
Bridge Unit BU6500 (D407) Folder FD6500A (B889)
141
2
Summary of Contents for BE-C1 D046
Page 1: ...Model Be C1 Machine Code D046 D049 Field Service Manual August 2008 Subject to change...
Page 2: ......
Page 22: ...Configuration 3 Main Machine Folder FD6500B B890 2 Installation 20 2...
Page 67: ...Paper Cassette Type 7140 D395 65 2...
Page 180: ...23 Reattach cover A x1 24 Reattach cover A x3 2 Installation 178 2...
Page 256: ...2 Installation 254 2...
Page 258: ...3 Preventive Maintenance 256 3...
Page 287: ...10 Remove the CIS unit 1 Scanner Unit 285 4...
Page 296: ...9 Remove the original junction gate 1 4 Replacement and Adjustment 294 4...
Page 446: ...6 Troubleshooting 444 6...
Page 447: ...Model Be C1 Machine Code D046 D049 Appendixes August 2008 Subject to change...
Page 448: ......
Page 462: ...1 Appendix Specifications 14 1...
Page 463: ...2 Appendix Overview Overview Machine Layout 1 Image Writing Unit 15 2...
Page 528: ...7 Appendix Jam Detection 80 7...