2.
Check the magnification ratio and adjust using the following SP mode if necessary.
SP No.
SP Name
Adjustment Range
SP4-008-001
Sub scan Mag. Adj
±1.0 %
ADF Image Adjustment
Registration
A: Leading Edge Registration
B: Side-to-side Registration
• Make a temporary test chart as shown above using A3/DLT paper.
1.
Place the temporary test chart on the ADF and make a copy from one of the feed stations.
2.
Check the registration, and adjust using the following SP modes if necessary.
SP No.
SP Name
Adjustment Range
SP6-006-001
ADF Adjustment SideEdge: Front
±3.0 mm
SP6-006-002
ADF Adjustment SideEdge: Rear
±3.0 mm
SP6-006-003
ADF Adjustment LeadingEdge: Front
±5.0 mm
SP6-006-004
ADF Adjustment LeadingEdge: Rear
±5.0 mm
Adjustment after Replacement
143
Summary of Contents for Bc-C1
Page 1: ...Model Bc C1 Machine Code D245 D246 D247 Field Service Manual June 2015...
Page 2: ......
Page 24: ...Drive Unit No Description No Description 1 Main motor 1 Product Information 22...
Page 60: ...2 Installation 58...
Page 76: ...2 Open the document table B 3 ADF rear cover A x 2 4 Replacement and Adjustment 74...
Page 83: ...9 Harness guide A x 5 x 4 x1 10 Hinge A x 4 11 Bracket A x 4 ADF Unit 81...
Page 85: ...2 White plate guide A x 1 3 ADF registration sensor A x 1 x 1 x 1 ADF Unit 83...
Page 129: ...9 Close the transfer guide unit 10 ID sensor A x 1 Duplex Unit 127...
Page 141: ...3 Registration clutch A x 1 Electrical Components 139...
Page 189: ...Test Page Registration Page Test Pattern Printing 187...
Page 196: ...5 System Maintenance 194...
Page 235: ...Sensor Locations Jam Detection 233...
Page 236: ...MEMO 234...
Page 237: ...MEMO 235...
Page 238: ...MEMO 236 EN...
Page 239: ...Model Bc C1 Machine Code D245 D246 D247 Appendices June 2015...
Page 240: ......
Page 242: ...2...
Page 264: ...1 Appendices Specifications 24...
Page 268: ...MEMO 28 EN...