IMAGE FUSING AND PAPER EXIT
SM
6-55
G065
Det
a
iled
De
s
c
ri
ptions
Fusing Idling Temperature
If copies are not sufficiently fused soon after the main power switch is turned on,
fusing idling should be enabled with SP1103-01.
When fusing idling is enabled, it is done when the temperature reaches the re-load
temperature. The re-load temperature can be adjusted with SP1105-05, 06.
In the opposite case, even if fusing idling is disabled, it is done if the temperature at
power-up
≤
15
°
C
The fusing idling time is as follows.
Fusing Idling Mode
Temperature at power-on
0: Disabled
1: Enabled
SP1103-01
15
°
C or less
30 s
30 s
Higher than 15
°
C
Not done
30 s
SP1103-02
6.13.8 OVERHEAT PROTECTION
If the hot roller temperature becomes greater than 250
°
C, the CPU cuts off the
power to the fusing lamp, and SC543 (Fusing Overheat Error) will be displayed.
Even if the thermistor overheat protection fails, there is a thermostat in series with
the common ground line of the fusing lamp. If the temperature of the thermostat
reaches 210
°
C, the thermostat opens, removing power from the fusing lamp. At the
same time, the machine stops operating. At this time, SC542 (Fusing Temperature
Warm-up Error) will be displayed.
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA
Summary of Contents for Aficio AP-4510 G065
Page 1: ...G065 SERVICE MANUAL 001269MIU RICOH GROUP COMPANIES C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 2: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 3: ...G065 SERVICE MANUAL RICOH GROUP COMPANIES C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 4: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 5: ...G065 SERVICE MANUAL 001269MIU C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 6: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 8: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 10: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 12: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 20: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 24: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 26: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 27: ...INSTALLATION C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 28: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 61: ...PREVENTIVE MAINTANENCE C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 62: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 66: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 67: ...REPLACEMENT AND ADJUSTMENT C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 68: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 137: ...TROUBLESHOOTING C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 138: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 156: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 157: ...SERVICE TABLES C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 158: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 202: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 203: ...DETAILED DESCRIPTIONS C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 204: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 261: ...BRIDGE UNIT B397 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 262: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 269: ...SPECIFICATIONS C PIA N O CONTROLADA C PIA N O CONTROLADA...