DRUM CHARGE
G065
6-18
SM
6.6.2 CHARGE ROLLER VOLTAGE CORRECTION
Correction for Environmental Conditions
The voltage transferred from roller to drum could vary with the temperature and
humidity around the drum charge roller. The lower the temperature or humidity, the
higher the applied voltage required.
The ID sensor measures the effects of ambient conditions, and any small change
in drum potential caused by changes in temperature/humidity is reflected in the
amount of toner transferred to the drum.
This measurement is done immediately after the ID sensor pattern for toner density
control. After creating ID sensor pattern [A], another pattern [B] is made. To do this,
the LD switches off, the charge roller voltage drops, and the drum potential is
reduced to –600 V. At the same time, development bias returns to –550 V. The
drum potential is now slightly higher than the development bias, so only a very
small amount of toner transfers to the drum. The ID sensor measures the density of
pattern [B], and Vsdp, the output voltage, is compared with Vsg which was read
from the bare drum at the same time.
t
Vsp (0.31V)
Vsdp (3.50V)
Vsg (4.00V)
– 1 5 0 V
– 3 8 0 V
– 5 5 0 V
– 5 4 0 V
– 9 5 0 V
– 1 4 8 0 V
Charge Voltage
Laser Diode
O n
Off
Drum Potential
Development Bias
ID Sensor Output
Sub Scan Direction
3 cm
3 cm
3 cm
ID Sensor Pattern
G065D506.WMF
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA
Summary of Contents for Aficio AP-4510 G065
Page 1: ...G065 SERVICE MANUAL 001269MIU RICOH GROUP COMPANIES C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 2: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 3: ...G065 SERVICE MANUAL RICOH GROUP COMPANIES C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 4: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 5: ...G065 SERVICE MANUAL 001269MIU C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 6: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 8: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 10: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 12: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 20: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 24: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 26: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 27: ...INSTALLATION C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 28: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 61: ...PREVENTIVE MAINTANENCE C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 62: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 66: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 67: ...REPLACEMENT AND ADJUSTMENT C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 68: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 137: ...TROUBLESHOOTING C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 138: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 156: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 157: ...SERVICE TABLES C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 158: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 202: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 203: ...DETAILED DESCRIPTIONS C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 204: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 261: ...BRIDGE UNIT B397 C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 262: ...C PIA N O CONTROLADA C PIA N O CONTROLADA...
Page 269: ...SPECIFICATIONS C PIA N O CONTROLADA C PIA N O CONTROLADA...