Rice Lake TC-1200 Operation Manual Download Page 38

 

35 

13.  Conversion Table of Units 

Unit Gram 

carat 

Ounce 

Pound 

troy 

ounce 

Penny 

Weight 

1

g

 

0.03527  

0.00220  

0.03215  

0.64301  

1ct 

0.2 

0.00705  

0.00044  

0.00643  

0.12860  

1oz 

28.34952  

141.74762   1 

0.06250  

0.91146  

18.22917  

1lb 

453.59237   2267.96185   16 

14.58333  

291.66667  

1ozt 

31.10348  

155.51738   1.09714  

0.06857  

20 

1dwt 

1.55517  

7.77587  

0.05486  

0.00343  

0.05 

1GN 

0.06480  

0.32399  

0.00229  

0.00014  

0.00208  

0.04167  

1tl (HK) 

37.429 

187.145 

1.32027  

0.08252  

1.20337  

24.06741  

1tl (SGP,Mal) 

37.79936  

188.99682   1.33333  

0.08333  

1.21528  

24.30556  

1tl (Taiwan) 

37.5 

187.5 

1.32277  

0.08267  

1.20565  

24.11306  

1mom 

3.75 

18.75 

0.13228  

0.00827  

0.12057  

2.41131  

1to 

11.66380  

58.31902  

0.41143  

0.02571  

0.37500  

7.5 

 
 

unit Grain 

tael 

(Hong Kong) 

tael  

(Singapore, 

Malaysia) 

tael   

(Taiwan) 

momme Tola 

1

g

 

15.43236  

0.02672  

0.02646  

0.02667  

0.26667  

0.08574  

1ct 

3.08647  

0.00534  

0.00529  

0.00533  

0.05333  

0.01715  

1oz 

437.5 

0.75742 

 0.75 

0.75599 

 7.55987 

 2.43056 

 

1lb 

7000 

12.11874  

12 

12.09580  

120.95797   38.88889  

1ozt 

480 

0.83100 

 0.82286 

 0.82943 

 8.29426 

 2.66667 

 

1dwt 

24 

0.04155 

 0.04114 

 0.04147 

 0.41471 

 0.13333 

 

1GN 

0.00173 

 0.00171 

 0.00173 

 0.01728 

 0.00556 

 

1tl (HK) 

577.61774   1 

0.99020  

0.99811  

9.98107  

3.20899  

1tl (SGP,Mal) 

583.33333   1.00990  

1.00798  

10.07983  

3.24074  

1tl (Taiwan) 

578.71344   1.00190  

0.99208  

10 

3.21507  

1mom 

57.87134  

0.10019  

0.09921  

0.1 

0.32151  

1to 

180 

0.31162  

0.30857  

0.31103  

3.11035  

 

Summary of Contents for TC-1200

Page 1: ...Operation Manual Function Zero Tare Memory On Off Target IMPORTANT To ensure safe and proper use of the balance please read this manual carefully After reading this manual store it in a safe place nea...

Page 2: ......

Page 3: ...the large liquid crystal display provides excellent visibility and the instrument s high speed and stability intrinsic to a tuning fork design help boost operational efficiency Before using the balan...

Page 4: ...g Units of Measurement 15 5 2 Setup of Units of Measurement 15 6 Counting Pieces 17 6 1 Sampling 17 6 2 Increasing the Counting Accuracy Memory Update Method 19 7 Measuring Percentage 21 8 Limit Funct...

Page 5: ...This term indicates steps that the user should take to ensure the quality and reliability of the balance Meanings of Symbols Each symbol is accompanied by an instruction Mandatory Symbol Indicates a m...

Page 6: ...k Keep Dry Do not use the balance in a location were it may be subjected to excess moisture Electric shock or short circuiting could occur The balance may be corroded with resultant malfunction Do Not...

Page 7: ...crease in the balance may lead to inaccurate measurement Unplug Adapter If the balance is to be unused for an extended period of time unplug the adapter This conserves power and prevents deterioration...

Page 8: ...LCD See page 6 Level for checking the level of the balance Turn the adjusters until The bubble rests in the center of the red circle Operation keys see page 7 Adjusters Round pan type Total of two one...

Page 9: ...limit function is active mom Momme M Display of set values from memory If a value is flashing it is being saved CAL Stays on and flashes while span adjustment is in progress Bar graph ct carat oz oun...

Page 10: ...mit function Function Function key Brief press toggle switches the units to be displayed in succession g Pcs etc Brief press moves the flashing digit in the setup of a limit value when using the value...

Page 11: ...e exact level of the balance Function Zero Tare Memory On Off Target Turn the adjusters feet until the bubble rests in the center of the red circle on the level Round pan type total of two adjusters o...

Page 12: ...0 00 0 00 0 Function Zero Tare Memory On Off Target Function Zero Tare Memory On Off Target Function Zero Tare Memory On Off Target Function Zero Tare Memory On Off Target Press the Function key Each...

Page 13: ...ate only the weight of the sample loaded in the tare Weighing only the weight of an added sample 4 Resetting the indication to zero 0 00 Function Zero Tare Memory On Off Target Press the Zero Tare key...

Page 14: ...stability indicator will disappear When a displayed value flickers or the stability mark flashes on and off it is likely that the balance is being affected by wind or other vibrations Use the windshie...

Page 15: ...ess the Function key The indication changes to the next item 2 SEL 0 Limit function 3 Selecting an item 3 A O 1 Function Zero Tare Memory On Off Target Pressing the Function key advances the function...

Page 16: ...ues are set up judges among HI OK and LO Auto zero zero tracking 3 A O 0 Disable This function automatically sets the zero point exactly to zero to prevent slight deviations 1 Enable Auto power off 4...

Page 17: ...ption of Functions cont 4 3 Interface Section denotes a factory setting The data interval in continuous output mode is 0 1 to 1 second The interval varies depending on weighting conditions and other f...

Page 18: ...en simply by pressing the Function key For more information on the units of measurement that can be set here please refer to 4 2 Description of Functions on page 13 Example To change the default facto...

Page 19: ...nits of measurement Function Zero Tare Memory On Off Target g lb Press the Function key Each press advances through the units of measurement to be displayed The balance is shipped from the factory wit...

Page 20: ...pcs Measured number of samples If samples to be counted deviate widely in weight or a higher measure of accuracy is desired it is recommended that users use the Raising the Counting Accuracy method T...

Page 21: ...value Press the Zero Tare key Each press of the key changes the value on the right end Select the desired value If the sampling number need not be changed go on to the next step 5 Loading samples on...

Page 22: ...changed 1 Loading samples on 10 Load the number of samples displayed Count the samples precisely and load them on to the center of the measurement pan 2 Saving the samples 10 10 pieces saved Function...

Page 23: ...After the unit weight of the samples has been saved the display begins to flash indicating that the Memory Update Method is still running 5 Repeating the addition and saving of samples Function Zero...

Page 24: ...arget Press the Function key to disaplay 2 Setting the reference value Function Zero Tare Memory On Off Target P SET Press the Target key The display begins flashing P SEt The balance is now ready for...

Page 25: ...Key Points of the Procedure 22...

Page 26: ...it value is entered with a key stroke The limit values entered are held in memory even when the balance is powered down The respective limit values for weight mode counting mode and percentage mode ar...

Page 27: ...the Zero Tare key to select the desired condition 5 Setting the judgement range 22 l 1 Function Zero Tare Memory On Off Target Judged entire range 22 l 0 Function Zero Tare Memory On Off Target Judged...

Page 28: ...Tare Memory On Off Target Press the Memory key After the lower limit value has been saved the balance displays it briefly and proceeds to the following setup If One point setup was chosen the setup is...

Page 29: ...ng a digit 000 05 Function Zero Tare Memory On Off Target Press the Function key The flashing moves to the digit on the immediate left Each time the key is pressed the flashing digit moves one positio...

Page 30: ...ing H SET Upper limit value displayed Lower limit value displayed Measurement mode restored Conti sing 0 00 77 38 233 45 2 If you make a mistake press the Function key during the setup of actual quant...

Page 31: ...ment function cal Func Key released Function Zero Tare Memory On Off Target Function Zero Tare Memory On Off Target Pressed continuously Press and hold down the Function key Release the key when the d...

Page 32: ...t Load the calibration weight in the center of the balance The display flashes indicating that capacity point calibration is in progress 5 Terminating the span adjustment on f s 200 00 When the calibr...

Page 33: ...arge the battery with a weak current when the power is switched on UOvercharging will also decrease battery lifeU 2 When the balance is used for the first time after purchase the operating time may be...

Page 34: ...te the Memory Update Method 19 o Err appears before the capacity is reached Gross weight exceeded the capacity of the balance weight range container weight of sample A section of the mechanism is dama...

Page 35: ...eight in percentage mode g 10 10 10 100 Weight measuring method Tuning fork vibration method Calibration method With external calibration weight Pan Size mm 180 x 160 12 2 Common Specifications 1 Tare...

Page 36: ...0 00005 0 00005 0 0005 ozt 7 13 19 38 0 0005 0 0005 0 0005 0 005 dwt 140 270 390 770 0 01 0 01 0 01 0 1 grain 3300 6400 9500 18000 0 2 0 2 0 2 2 Hong Kong 5 8 11 16 32 0 0005 0 0005 0 0005 0 005 Sing...

Page 37: ...2 13 26 0 0005 0 0005 0 0005 0 005 ozt 70 130 190 380 0 005 0 005 0 005 0 05 dwt 1400 2700 3900 7700 0 1 0 1 0 1 1 grain 33000 64000 95000 2 2 2 Hong Kong 58 110 160 320 0 005 0 005 0 005 0 05 Singap...

Page 38: ...5 24 11306 1mom 3 75 18 75 0 13228 0 00827 0 12057 2 41131 1to 11 66380 58 31902 0 41143 0 02571 0 37500 7 5 unit Grain tael Hong Kong tael Singapore Malaysia tael Taiwan momme Tola 1g 15 43236 0 0267...

Reviews: