Appendix
41
8.1.10 Tare, Zero key and REGULAT Parameter
The function of the
TARE
and
ZERO
keys depends on the value specified for the
REGULAT
parameter. Table 8-11
below describes the function of these keys for each of the regulatory modes.
Table 8-10. Regulate Parameter Values
REGULAT
parameter value
Weight on scale
Tare in system
Key press function
KTARE
KZERO
USA
zero or negative
no
no active
zero
yes
clear tare
positive
no
tare
yes
tare
CANADA
zero or negative
no
no active
zero
yes
clear tare
positive
no
tare
yes
no active
EUROPE
zero or negative
no
no active
zero
yes
clear tare
zero and clear tare
positive
no
tare
zero
yes
tare
zero and clear tare
NONE
zero or negative
no
tare
zero
yes
clear tare
positive
no
tare
yes
clear tare
Note
• ZERO if in Standstill.
• ZERO if Weight is within ZRANGE. No action if weight is outside of ZRANGE.
• CLEAR TARE or ZERO force indicators into gross mode.
• TARE force indicator into net mode
8.2
Conversion Factors and Continuous Output Format
8.2.1
Conversion Factors - Secondary Unit = Primary Unit x Multiplier
Table 8-11. Conversion Factors
Primary Unit
X Multiplier or Divisor
Secondary Unit
KG
x 2.20462262184878
lb
KG
x 1000
g
KG
x 35.2739619495804
oz
lb
x 2.20462262184878
kg
lb
x 453.59237
g
lb
x 16
oz
g
/ 1000
kg
g
x 453.59237
lb
g
x 0.00228571428571429
oz
oz
/ 35.2739619495804
kg
oz
/ 16
lb
oz
/ 0.00228571428571429
g