Configuration
13
3.0
Configuration
The following sections provide graphic representations of the indicator menu structures. The top level menu
structure of the weight indicator is as follows:
CONFIGURATION
FORMAT
CALIBRATION
SERIAL
PROGRAM PRINT
FORMAT
TIME
DATE
VERSION
SET POINTS
&RQIL*
IRUPDW
&$/LEU
6(ULD/
3UR*UP
3)RUPW
6(W3W6
WLP(
G$W(
Y(U6
MODEL
02'H/
SERIAL NUMBER
6Q
Figure 3-1. Configuration Menu
The following table gives a brief introduction to what each menu item does.
Table 3-1. 120 Plus Menu Structure
Main Menu
Function
Configuration Menu
Sets parameters affecting weighing function such as:
• Number of full scale graduations
• Range within which the scale can be zeroed
• Change in load at which the scale will exit the stable condition
• Regulatory mode
Format Menu
Sets the format for calculation and display of various units like:
• Primary and secondary units
• Multiplier and decimal point location
• Rate at which the display is refreshed
Calibration Menu
Used for calibrating the indicator
Serial Menu
Configures the parameters of the serial ports
Program Menu
Sets the power up mode, shut down method, back light, keyboard
lock, and consecutive number values
Print Format Menu
Sets the print format used for print tickets
Set Points Menu
Sets the parameters for the two setpoints, and the digital inputs
Time Menu
Display or set the current time
Date Menu
Display or set the current date
Version Menu
Displays the installed software version number
Model
Displays the model number of the indicator
Serial Number
Displays the serial number of the indicator
The front panel keys can be used as directional keys to navigate through the menus in configuration mode. An
example of navigation process is shown below in Figure 3-2.
1st Level
Parameter
2nd Level
Parameter
1st Level
Parameter
2nd Level
Parameter
Present value
Value
Value
Value