20
120 Plus Digital Weight Indicator Technical Manual
3.4
Serial Menu
The items in this menu are used to configure the serial port used for transferring data between the indicator and a
PC or printer. To configure items in this menu, press the setup switch and then the right arrow key three times.
The Serial menu is shown below:
SERIAL
BAUD
1200
38400
4800
19200
9600
2400
BITS
8NONE
70DD
7EVEN
7SPACE
TERMINATION
CR
CR/LF
ECHO
ON
OFF
GERMAN
ENGLIS
STREAM
DELAY
250MS
1SEC
500MS
ADDRESS
00
Number
WHAT
?
??
PRN
MONBAT
ON
OFF
CINSTR
ON
OFF
DATA
TRANSMISSION
PORT
STREAM
OFF
6(UL$/
ELECTRONIC DATA PROCESSING
(G3
3ULQW
LANGUAGE
/Q*X*(
$GGU(6
(&+R
W(UP
ELW6
E$8G
EDP
PRN
EDP
2SEC
8SEC
4SEC
STMSTA
:+$W
0RQE$W
6WP6W$
&LQ6WU
6WPG/<
6WU($P
3UQG(6
BAUD
1200
38400
4800
19200
9600
2400
BITS
8NONE
70DD
7EVEN
7SPACE
TERMINATION
CR
CR/LF
W(UP
ELW6
E$8G
15SEC
NONE
ON
OFF
OFF
Figure 3-7. Serial Menu
Parameter
Options
Description
Electronic Data
Processing
(EDP)
Baud
Bits
Term
Echo
Addres
Specifies port settings for baud rate, data bits, termination characters, and end- of-line
delay used by the EDP port.
Baud
9600
1200
2400
4800
19200
38400
Baud Rate. Selects the transmission speed for the EDP port.
Bits
8NONE
7ODD
7EVEN
7SPACE
Selects number of data bits and parity of data transmitted from the EDP port.
Table 3-5. Serial Menu