background image

Page 11 / 12 

 

EN

 

 

Original

 

Instructions

  

I. Parts List 
II. Characteristics 

III. Safety instructions 
IV. Getting Started 

V. Operation 
VI. Maintenance and Storage 

 
 
 

WARNING

:  

Carefully read this instruction manual before operating this appliance.  
Incorrect operation may cause injury and/or damages. 

Please keep this manual for future reference. 
 

 

Warning: This pump is not intended for swimming pools.   
Under no circumstances should it be used for the cleaning or maintenance of swimming pools. 
This pump is not intended for pumping drinking water. 
 

 

I. PARTS LIST 

See Fig.1

 

 
 
II. CHARACTERISTICS 

See table 1 

 
 
III. SAFETY INSTRUCTIONS 
 

Before using this product, read and understand all safety instructions. 
Always follow the safety instructions to minimize risk of damage to property, and to 
minimize any risk of damages and injuries to persons and animals. 
 

Symbols 

 

 

Caution! Risk of injury and/or damage and/or deterioration of product in case of 
non-compliance to safety requirements.

 

Read the instructions manual.  
 

 

Keep persons (esp. children) and animals away from product and working area. 

 

Disconnect product from its power source before maintenance, cleaning or any 
intervention on product; or when you do not use product. 
Disconnect product from its main power source, if product, power cable, or 
extension cord is damaged or cut during operation.  
Unplug product by pulling the plug. Do not pull the cable.

 

Do not dispose of this product with household rubbish. 
Dispose of this product in the nearest recycle centre. 
Please contact your local authority or local recycle centre for further information for 
its safe disposal. 

 

Summary of Contents for Ribiland 516231

Page 1: ...Manuel d instructions et d utilisation EN MULTISTAGE WATER PUMP WITH VFD User and maintenance manual Imp par by Ribimex S A 56 Route de Paris FR 77340 Pontault Combault Imp da Ribimex Italia SRL Via I...

Page 2: ...e toujours suivre les consignes de s curit afin de r duire les risques d incendie de choc lectrique de blessures et de dommages Symboles Signale un risque de blessures graves et ou dommages et ou de d...

Page 3: ...uit appropri Ne pas forcer des produits ou accessoires l gers effectuer des travaux normalement r alis s avec des produits plus lourds 8 S habiller correctement Lors de l installation ne pas porter de...

Page 4: ...uates doivent utiliser ce produit Cet appareil peut tre utilis par des enfants g s de 8 ans et plus et des personnes dont les capacit s physiques sensorielles ou mentales sont r duites ou des personne...

Page 5: ...sa source d alimentation 4 1 D ballage Retirez le produit de son emballage V rifiez que le produit ne pr sente de d g ts Contenu pompe variateur VFD cuve manom tre raccords laiton connecteur 5 voies P...

Page 6: ...graphes suivants f S assurer que le branchement lectrique soit prot g contre les projections d eau g En cas d utilisation l ext rieur les connexions lectriques doivent tre prot g es contre les clabous...

Page 7: ...a pas besoin de s amorcer d accumuler de la pression et de remplir les tubes lors de chaque d marrage Ce type de montage permet de minimiser l usure et d conomiser du temps et de l nergie En outre il...

Page 8: ...TE Cette pompe n est pas destin e au nettoyage et aux autres op rations d entretien des piscines La pompe ne doit pas tre utilis e dans des fontaines ext rieures des bassins de jardin et endroits anal...

Page 9: ...toyer les parties en mati re plastique l aide d un chiffon doux et propre Ne pas utiliser de produit d entretien agressif solvants d tergents ni d ponge abrasive ni d objets tranchants ou pointus 6 2...

Page 10: ...aux r glementations locales relatives la protection de l environnement Nos conditions de garantie sont disponibles aupr s de notre STAV et sur notre site internet Pour toute demande de r paration sou...

Page 11: ...he safety instructions to minimize risk of damage to property and to minimize any risk of damages and injuries to persons and animals Symbols Caution Risk of injury and or damage and or deterioration...

Page 12: ...g parts Wear protecting hair covering to contain long hair 9 Use protective equipment When installing wear protective equipment appropriate to working conditions and work environment Wear protective h...

Page 13: ...ication in order to avoid any danger If the power cable or extension cord is damaged or cut during operation immediately disconnect plug from its main power source Do not touch the cable or extension...

Page 14: ...e installed in accordance with local standards and by a qualified person we recommend you to contact an electrician The fixed pipeline that will connect the pump must include a separation device havin...

Page 15: ...ension on the pump If the conveying medium is contaminated a suction filter must be used to protect the pump from sand and dirt IMPORTANT It is highly recommended to install a non return valve in the...

Page 16: ...p treated water The pump must be installed in a dry ventilated location not exposed to bad weather excessive heat and cold The maximum suction height must not exceed See table 1 When correctly install...

Page 17: ...ate the pump without there being water in the pump body Prolonged operation of the pump while the discharge line valve is closed may seriously damage the pump Where there is a power failure it is pref...

Page 18: ...frequently 5 Pump overloaded Seek assistance from vendor or authorised service centre 6 3 Storage Product must be stored in a dry location Always lock up product and keep out of reach of children 6 4...

Page 19: ...capteur Alarme du VFD Alarme de la pomps Mode automatique A courrant en Amp re HZ fr quence en Hertz BAR pression VFD operation VFD Stop VFD Parameter 1 VFD Parameter 2 Sensor Alarm VFD Alarm Pump Al...

Page 20: ...yez sur le bouton STOP pendant env 3 secondes L indication AUTO appara tra sur l cran En mode automatique la pompe fonctionnera en fonction de la pression d finie To change the operation method please...

Page 21: ...ency 0 1 20 0 Hz 1 5 1 5 P 06 Tension min Min Voltage 3 100 VAC 15 15 P 07 Temps d acc l ration ACC Time 3 0 99 9 Sec 4 0 3 5 P 08 Temps de d c l ration DEC Time 3 0 99 9 Sec 4 0 3 5 P 09 Mode d arr t...

Page 22: ...0 B 04 Faible pression Low pressure 0 2 20 Bar 0 4 0 5 B 05 Temps d arr t si faible pression Stop Time of Low pressure 0 Not use 1 999 Sec 20 20 B 06 Courant faible Low Current 0 5 5 0 A 3 3 3 3 B 07...

Page 23: ...normal du moteur de la pompe Overload on the inverter Abnormal operation of the motor pump V rifiez la pompe moteur Check the pump motor chec de la communication Fail communication Echec de communicat...

Page 24: ...ine 220 240V 10 50 60Hz 5 Tension V et courant A nominal de sortie Rated OUTPUT Voltage V and Current A 3Phase 220 240V 7A Puissance Power Max motor output 1100W 1 5HP Plage de fr quence de sortie Out...