ACCESSORIES
For connection and technical data of the accessories refer to the relevant
instruction booklets.
BATTERY CHARGE CARD
Cod. ACG4648
The time needed to completely charge the 12Vdc 2,2Ah batteries (n° 2 batteries
connected in series, optional cod. ACG9515), upon first installation, is 24 hours, with a
charging current of 0.03A.
POWER SUPPLY GATE OPEN INDICATOR AND STATE OF BATTERY (COM-
SIGNAL)
This indicator, in addition to signalling that the gate is open, emits 2 brief flashes
followed by a pause of 2 seconds when the gate is closed and there is no power supply,
indicating that it is functioning with the battery.
Functioning of the gate is guaranteed up to a charging level of approximately 20V,
following which the gate blocks and the indicator flashes continuously to signal that the
battery is low.
Only when voltage returns will the indicator go out and all the controls be restored
(obviously the battery will only recharge when there is voltage).
N.B.: if the bulbs are used excessively, the logic of the control unit may be compromised
with possible blocking of all operations.
FUNCTIONING IN A BLACKOUT (WITH BATTERIES)
If batteries are connected to the control unit, when there is a power cut the functioning of
the gate is guaranteed up to a charging level of approximately 20V, following which a
signal is sent by the recharge card to the control unit which blocks the gate and makes
the battery signal light flash.
Once voltage returns we recommend that the gate be fully opened. Allow the gate to
close by itself with automatic closure or wait for the flashing light to stop before giving the
command to close.
This operation will allow the gate to realign itself. In fact, if during the blackout the motors
were released and moved from the normal closing position, the first manoeuvre when the
power supply returns must be complete.
During this phase the safety devices are active.
RADIO TRANSMITTER MOON
FIT SYNCRO
FIT SYNCRO PHOTOCELLS FOR THE WALL-INSTALLATION
- code ACG8026
The range you can set Is 30÷60ft 49÷100”
You can fit many couples close together thanks to the synchronising circuit.
Add the
SYNCRO TRANSMITTER
, code ACG8028, for more than 2 photocells couples
(up to 4).
COUPLE OF BUILT-IN BOXES FOR THE FIT SYNCRO
code ACG8051
SPARK ANTENNA
code ACG5452
SPARK BLINKER
with in-built intermittent card
code ACG7061
BLOCK
BLOCK KEY SELECTOR FOR WALL-INSTALLATION
code ACG1053
BLOCK KEY SELECTOR TO BUILD-IN
code ACG1048
ACG6081
ACG6082
Summary of Contents for ABK0024
Page 4: ...I T A L I A N O Pag 4 di 28 COLLEGAMENTI ELETTRICI K2 24V Cod BC07059 K2 24V CRX Cod BC07058 ...
Page 16: ...Pag 16 di 28 K2 24V Code BC07059 K2 24V CRX Code BC07058 ELECTRIC CONNECTIONS E N G L I S H ...
Page 22: ...Pag 22 di 28 K2 24V Code BC07059 K2 24V CRX Code BC07058 ELEKTROANSCHLÜSSE D E U T S C H ...