background image

En-4

OPERATING MANUAL

5

POWERFUL button

The product will operate at maximum power, which is convenient 
when you want to quickly cool down or warm up the room.
When you press the button to start the POWERFUL operation, the 
indoor unit emits 3 short beeps.
POWERFUL operation is automatically turned off in the following 
situations:
• Adjusted room temperature reached to the de

fi

 ned temperature in 

temperature setting in COOL, DRY, or HEAT mode.

• 20 minutes have passed after 

fi

 nishing the POWERFUL operation 

mode setting.

It is not turned off automatically during setting of the POWERFUL 
operation.

Notes:

• The air

fl

 ow direction and the fan speed are controlled automatically.

• This operation cannot be performed simultaneously with ECONOMY 

operation.

To return to normal operation, press the button again. Then the indoor 
unit emits 2 short beeps.

6

MIN. (MINIMUM) HEAT button

Starts MIN. HEAT operation that maintains the room temperature at 
50 °F (10 °C) so as to prevent the room temperature to drop too low.
When you press the button to start the MIN. HEAT operation, the 
indoor unit emits 2 short beeps and the ECONOMY indicator (green) 
turns on.

Notes:

• In MIN. HEAT operation mode, only vertical air

fl

 ow direction can be 

adjusted by using Vertical SET button.

• HEAT mode will not be performed if the room temperature is warm 

enough.

• In multi-type air conditioning system, if other indoor unit is in HEAT 

mode, the temperature of the room where MIN. HEAT operation is 
performed will rise. When performing MIN. HEAT operation, all the 
indoor units should be run in MIN. HEAT operation mode.

To return to normal operation, press the Start/Stop button.
The ECONOMY indicator turns off.

7

Signal transmitter

Aim at the signal receiver of the indoor unit properly.
• Signal transmit indicator   on the remote controller display shows 

that signal from the remote controller is being transmitted.

• Operating range is approximately 22 ft. (7 m).
• You will hear a beep if the transmitted signal has been sent properly. 

If there is no beep, press the button on the remote controller again.

8

FAN button

Controls the fan speed.

(AUTO)

(HIGH)

(MED)

(LOW)

(QUIET)

• When AUTO is selected, the fan speed is automatically adjusted 

according to the operation mode.

9

SWING button

Starts or stops automatic swing of the vertical air

fl

 ow direction louver.

• Each time you press the button, the vertical air

fl

 ow direction louver 

swings as follows:

COOL, DRY, or FAN 

mode

HEAT or FAN mode

1

2

3

7

6

5

4

1

2

3

4

5

6 7

Notes:

• SWING operation may stop temporarily when the fan in the unit is 

rotating at very low speed or is stopped.

• In FAN mode, either of swing direction 1 

 3 or 4 

 7 is performed 

in accordance with the vertical air

fl

 ow direction previously set before 

you start the SWING operation.

Remote Controller Overview and Operations

0

Vertical SET button

Adjusts the vertical air

fl

 ow direction.

See page 5

A

SLEEP timer button

Activates the SLEEP timer that helps you to fall asleep comfortably 
with gradual temperature control.

B

Timer CANCEL button

Cancels the set timer.

C

RESET button

When you press the RESET button, press it gently by using the tip of 
a ballpoint pen or other small object in correct direction as shown in 
this 

fi

 gure.

RESET

See page 3

D

CLOCK ADJUST button

Used for adjusting the clock.

See page 5

E

OFF timer button

Activates the OFF timer.

See page 5

F

ON timer button

Activates the ON timer.

G

SELECT button

Used for adjusting the clock or timer.

H

ECONOMY button

Starts or stops ECONOMY operation that saves more electricity 
consumption than the other operations with a conservative adjustment 
of the room temperature.
When you press the button, the ECONOMY indicator on the indoor 
unit turns on.
• In COOL or DRY mode, the room temperature will be adjusted at a 

few degree higher than the de

fi

 ned temperature.

  In HEAT mode, the room temperature will be adjusted at a few 

degree lower than the de

fi

 ned temperature.

• Especially in COOL or DRY mode, you can have improved 

dehumidi

fi

 cation without signi

fi

 cantly lowering the room temperature.

Notes:

• In COOL, HEAT, or DRY mode, the maximum output of this 

operation is approximately 70 % of usual air conditioning operation.

• When at FAN mode, the fan speed will slow down by 1 step. (high > 

medium, medium > low, low > quiet, quiet > more quiet)

• This operation cannot be performed during temperature monitoring 

by AUTO mode.

• In multi-type air conditioning system, ECONOMY operation is 

performed only on the indoor unit whose ECONOMY button on the 
corresponding remote controller is pressed.

I

°C / °F button

Select the preferred temperature unit.
(Factory setting is °F.)

:  

The setting must be done while the indicator stays solid.

 :  The button is controllable only when the air conditioner is on.

9333003269_OM.indb   4

9333003269_OM.indb   4

2016/11/28   下午 05:46:25

2016/11/28   下午 05:46:25

Summary of Contents for RIWH07AVFJ

Page 1: ...re that they do not play with the appliance Do not start or stop the operation of this product by inserting or pulling out the power plug or by turning on or off the circuit breaker Do not use flammab...

Page 2: ...direction louver Power diffuser 3 7 6 5 4 2 1 3 2 1 4 In SWING operation power diffuser does not move 6 Drain hose 7 Remote controller signal receiver CAUTION For appropriate signal transmission betwe...

Page 3: ...ng 8 Press the C F button to select the preferred temperature unit Factory setting is F Notes Use specified type of batteries only Do not mix different types or new and used batteries together Batteri...

Page 4: ...rection louver Each time you press the button the vertical airflow direction louver swings as follows COOL DRY or FAN mode HEAT or FAN mode 1 2 3 7 6 5 4 1 2 3 4 5 6 7 Notes SWING operation may stop t...

Page 5: ...nce with the set time shown as follows The air conditioner completely turns off after the set time has elapsed In HEAT mode Set temperature Set time 1 hour Set time 1 hour 1 5 hour 30 min 2 F 1 C 4 F...

Page 6: ...ruption such as a blackout the air conditioner stops once But it restarts automatically and performs previous operation when the power supply is resumed If any power interruption occurs after the time...

Page 7: ...internal parts throughly before you perform normal operation Additional inspection After long period of use accumulated dust inside the indoor unit may reduce the product performance even if you have...

Page 8: ...the Automatic Defrosting operation while the OPERATION indicator is flashing 6 In DRY mode the indoor unit operates at low fan speed to adjust the room humidity and may stop from time to time When the...

Page 9: ...rant ou en d connectant la prise d alimentation ou bien en activant ou en d sactivant le disjoncteur N utilisez pas de gaz inflammables proximit de cette unit Ne vous exposez pas directement au flux...

Page 10: ...vertical Diffuseur de puis sance 3 7 6 5 4 2 1 3 2 1 4 En fonctionnement SWING OSCILLATION le diffuseur de puissance ne se d place pas 6 Tuyau de vidange 7 R cepteur du signal de t l commande ATTENTI...

Page 11: ...nfiguration d usine et le F Remarques Utilisez uniquement le type de piles sp cifi es Ne pas m langer diff rents types de piles ni de piles nouvelles et usag es ensemble Avec une utilisation normale l...

Page 12: ...volet de direction du flux d air vertical oscille comme suit Mode COOL REFROIDISSE MENT DRY D SHUMIDIFICA TION ou FAN VENTILATEUR Mode HEAT CHAUF FAGE ou FAN VENTILA TEUR 1 2 3 7 6 5 4 1 2 3 4 5 6 7...

Page 13: ...ne configur e En pareil cas l indicateur TIMER MINUTERIE de l unit int rieure clignote et vous devez rajuster le r glage Minuterie ON MARCHE ou minuterie OFF ARR T 1 Allumez l unit int rieure en appuy...

Page 14: ...il y a eu une d faillance de la minuterie Dans un tel cas r initialisez la minuterie pour le temps opportun Fonctionnements d fectueux caus s par d autres dispositifs lectriques L utilisation d autres...

Page 15: ...TILATEUR pendant une demi journ e afin de s cher compl tement les pi ces internes Inspections compl mentaires Apr s une longue p riode d utilisation la poussi re accumul e l int rieur de l unit int ri...

Page 16: ...UMIDIFICATION l unit int rieure fonctionne basse vitesse du ventilateur afin de r gler l humidit de la pi ce et peut s arr ter de temps en temps Lorsque la vitesse du ventilateur est r gl e sur QUIET...

Page 17: ...que no jueguen con el aparato No iniciar o detener el funcionamiento de este producto insertando o sacando el enchufe de la alimentaci n o de encender o apagar el interruptor de circuito No utilice g...

Page 18: ...n del aire vertical Difusor de po tencia 3 7 6 5 4 2 1 3 2 1 4 En la operaci n SWING VAIV N el difusor de potencia no se mueve 6 Manguera de drenado 7 Receptor de se al del control remoto ATENCI N Par...

Page 19: ...es de bater as tampoco combine nuevas con usadas Las bater as pueden usarse durante cerca de 1 a o en uso ordinario Si el rango del control remoto se acorta de manera evidente reemplace las bater as y...

Page 20: ...de direcci n del aire vertical oscila de la siguiente manera ModoCOOL ENFRIAMIENTO DRY DES HUMECTACI N oFAN VENTILADOR Modo HEAT CALEFACCI N O FAN VENTILADOR 1 2 3 7 6 5 4 1 2 3 4 5 6 7 Notas La opera...

Page 21: ...APAGADO AUTOM TICO controla el ajuste de temperatura autom ticamente de acuerdo con el tiempo establecido como se muestra a continuaci n El acondicionador de aire se apaga por completo una vez que tr...

Page 22: ...re acondicionado se detiene de inmediato Pero se reinicia autom ticamente y realiza la operaci n previa cuando se reanude la alimentaci n el ctrica Si la interrupci n de energ a se produce despu s del...

Page 23: ...artes internas completamente antes de llevar a cabo la operaci n normal Inspecci n adicional Despu s de un per odo prolongado de uso la acumulaci n de polvo dentro de la unidad de interior puede reduc...

Page 24: ...or OPERATION FUNCIONAMIENTO parpadea 6 En el modo DRY deshumectaci n la unidad de interior funciona a baja velocidad del ventilador para ajustar la humedad ambiente tal vez se detenga de vez en cuando...

Reviews: