INSTALLATION INSTRUCTIONS

General

NOTICE:

TheNationalFuelGasCode(NFGC)andCAN/CSAB149.1mandateamanualgasshut-offvalve.

SeeNFGC/B149.1forcompleteinstructions.Localcodesorplumbingauthorityrequirementsmayvaryfromthe

instructionsordiagramsprovidedandtakeprecedenceovertheseinstructions.

TypicalInstallationofDirect-VentWaterHeater

To Hot Water

Faucet(s)

Drain Valve

Wall

Plate

(Recommended)

Water

Filter

Cold Water Supply

Shut-Off Valve

Power

Supply

Cord

Union

Union

Union

Manual Gas

Supply Line

Shut-Off Valve

Downward Slope to

outside termination

Downward Slope to

outside termination

Manual Gas

Shut-Off Valve

(Supplied)

Cap

Sediment Trap

Outside

Wall

90˚

Elbow

Service

Valve

Service

Valve

Relief

Valve

Relief

Valve

(Supplied)

*Note: A flexible drain tube can be used

To

Suitable 

Drain

To

Suitable 

Drain

Condensate 

Drain*

Air Intake Pipe

Exhaust Vent Pipe

WaterHeaterInstallation(cont.)

Summary of Contents for CECOH160DV

Page 1: ...ry or property damage For Your Safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance To do so may result in an explosion or fire Inst...

Page 2: ...ol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and either the word DANGER WARNING CAUTION or NOTICE 2 These words mean...

Page 3: ...es are extremely dangerous DO NOT handle use or store gasoline or other flammable or combustible materials anywhere in the vicinity of a water heater or any other appliance Be sure to read and follow...

Page 4: ...operate Even when drained properly a small amount of water will remain in the water heater In cold weather conditions this water can freeze If this happens allow the defrost protection on the heater a...

Page 5: ...type Both natural gas and propane LP have an odorant added to aid in detecting a gas leak Some people may not physically be able to smell or recognize this odorant If you are unsure or unfamiliar wit...

Page 6: ...this label 2 Turn off all electric power to the appliance 3 Do not attempt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5...

Page 7: ...rmed only by qualified service personnel Make certain the power to the water heater is OFF before removing the unit cover panel Exposed electrical components and moving parts can cause personal injuri...

Page 8: ...tion instructions Do not attempt to repair or replace any part of your water heater unless it is specifically recommended in this manual All other servicing should be referred to a qualified service t...

Page 9: ...4 248 mm 21 4 59 mm 51 2 140 mm 61 8 156 mm 21 8 54 mm 37 8 98 mm 27 8 73 mm 41 8 105 mm 91 2 241 mm 11 2 38 mm Specifications Direct Vent Models 177 8 454 mm 185 8 473 mm 275 8 702 mm 93 4 248 mm 21...

Page 10: ...r 178 226 Shipping Weight lbs 81 81 Minimum Activation Flow Rate gpm 0 40 0 40 Extinction Flow Rate gpm 0 25 0 25 Hot Water Capacity gpm 35 F rise 8 5 9 5 Hot Water Capacity gpm 77 F rise 3 9 4 9 Defa...

Page 11: ...witch To Hot Water Faucet s Drain Valve Water Filter Cold Water Supply Shut Off Valve Note A flexible drain tube can be used To Suitable Drain To Suitable Drain Power Supply Cord Union Union Manual Ga...

Page 12: ...Line Shut Off Valve Manual Gas Shut Off Valve Supplied Cap Sediment Trap Service Valve Relief Valve Relief Valve Supplied Note A flexible drain tube can be used To Suitable Drain To Suitable Drain Co...

Page 13: ...y or death from scalds Children disabled and elderly are at highest risk of being scalded See instruction manual before setting temperature at water heater Feel water before bathing or showering Tempe...

Page 14: ...eater may not operate with a small water flow Increase the water flow and recheck If it still does not operate with the hot water faucet completely open increase the temperature setting on the remote...

Page 15: ...thods Do not operate without the condensate collector drain connected and routed to a proper drain that can handle corrosive condensate This could cause the system to malfunction or fail On a regular...

Page 16: ...the unit cover panel Turn on a hot water faucet While the water heater is operating inspect the main burner flames through the burner sight glass The flames should be blue when the main burner is firi...

Page 17: ...off and the electrical power supply disconnected Vacuum around the water heater to remove any dust dirt and or lint buildup Clean the water heater and the remote control with a damp soft cloth and mil...

Page 18: ...out of the line Clean the water filter under running water To remove severe sediment and dirt use a soft brush CAUTION Do not overtighten the water filter Overtightening can deform and or damage the f...

Page 19: ...ne to the drain After several gallons have drained release the lever handle to close the valve and stop draining NOTICE If the pressure relief valve on the hot water heater discharges periodically thi...

Page 20: ...disconnect the power supply at the circuit breaker box Open all hot water faucets Run the water until it is COLD then shut off the faucet Close the water shut off valve Using a suitable container to...

Page 21: ...not work properly until this water is thawed To put the water heater back in service Disconnect drain hose Make sure the drain valve is closed Reinstall the water filter in the base of the cold water...

Page 22: ...e water heater down to an ambient temperature of approximately 30 F 34 C These temperatures are all based on temperatures without wind The heater only protects the internal components of the water hea...

Page 23: ...le Cause Solution Not enough or no hot water 1 Unit is not ON 1 Turn on the unit by pressing the POWER ON OFF button 2 Water shut off valve is not completely opened 2 Check shut off valve and open com...

Page 24: ...g size 4 Bleed over in one of the hot water fixtures 4 Contact a dealer or a qualified service technician Water too hot 1 Temperature is set too high 1 Decrease the temperature setting at the remote c...

Page 25: ...nectors or other safety devices Refer repairs to a qualified service technician When an error code is displayed Turn off all the hot water faucets Turn off the water heater by pressing the POWER ON OF...

Page 26: ...t can be used for a while but contact a dealer or qualified service technician 93 The neutralizer must be replaced The unit cannot be used until the neutralizer is replaced Contact a dealer or qualifi...

Page 27: ...INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR Installation...

Page 28: ...s are used or stored Such liquids include gasoline LP gas butane or propane paint adhesives and their thinners solvents or removers Flammable vapors carry long distances from where they are used or st...

Page 29: ...ible and noncombustible construction are as follows 1 2 in 1 3 cm for sides 0 in 0 cm for rear with support bracket s 12 in 30 cm from the bottom top and front 12 min 300 mm 12 min 300 mm 1 2 min 13 m...

Page 30: ...ing a water heater in any of the following locations beauty shops dry cleaning establishments photo processing labs and storage areas for liquid and powdered bleaches or swimming pool chemicals These...

Page 31: ...r Heater To Hot Water Faucet s Drain Valve Wall Plate Recommended Water Filter Cold Water Supply Shut Off Valve Power Supply Cord Union Union Union Manual Gas Supply Line Shut Off Valve Downward Slope...

Page 32: ...ld Water Supply Shut Off Valve Hard Wire not supplied Union Manual Gas Supply Line Shut Off Valve Flue Terminal Cap Sediment Trap Manual Gas Shut Off Valve Supplied Water Filter Union Union Service Va...

Page 33: ...ter heater is attached to it This piece of wood can be installed inside or outside of the wall Use wood screws to secure brackets to wall If mounting to a concrete wall use lag bolts designed for conc...

Page 34: ...ing approved vent pipe material Use only 2 or 3 inch diameter pipe Refer to local codes for restrictions on the use of PVC CPVC or ABS pipe and fittings All exhaust venting materials for product insta...

Page 35: ...heater is being installed as a replacement for an existing water heater a thorough inspection of the existing venting and air intake system must be performed prior to any installation work Verify that...

Page 36: ...ce with the above provisions shall comply with NFPA 720 and be ANSI UL 2034 listed and IAS certified 3 SIGNAGE A metal or plastic identification plate shall be permanently mounted to the exterior of t...

Page 37: ...tal Vent Terminal Location Outside Walls Fixed Closed Fixed Closed Operable Operable V V V V V V X X V V Interior Wall Vent Terminal Air Supply Inlet Area Where Terminal is Not Permitted B B A J I B M...

Page 38: ...n 23 cm for water heaters greater than 10 000 Btuh 3 kW and less than or equal to 50 000 Btuh 15 kW 12 in 30 cm for water heaters greater than 50 000 Btuh 15 kW 6 in 15 cm for water heaters less than...

Page 39: ...it installation 24 in 61 cm and 36 in 91 4 cm for a three unit installation 24 in 61 cm 36 in 91 4 cm and 24 in 61 cm for a four unit installation Do not terminate vent directly on brick or masonry su...

Page 40: ...ve shelf precautions printed on the containers For applications below 32 F use only lower temperature type solvent cement Appropriate solvent and cleaner must be used for the type of vent pipe used PV...

Page 41: ...s a coupling to prevent the pipe from being pushed back into the structure The standard horizontal exhaust outlet termination is a 2 inch or 3 inch pipe which terminates 12 inches from the air intake...

Page 42: ...tional Ceiling Downward Slope towards termination Air Intake Vent Exhaust Vent Alternative horizontal vent termination kits are commercially available Please refer to the instruction sheet packaged wi...

Page 43: ...other means of support from a second location Determine the vent terminal height and install the vent pipe accordingly Refer to Vertical Vent Terminal Location on page 44 for clearance requirements In...

Page 44: ...4 ft 1 2 m D Required vent clearance from any forced air inlet including dryer and furnace air inlets 10 ft 3 m 6 ft 1 8 m E Minimum maximum horizontal dis tance between vent terminals 5 5 in 14 cm 24...

Page 45: ...LLATION INSTRUCTIONS Adjustable Roof Flashing Support Clamp Upward Slope Support Hanger Air Intake Pipe Exhaust Vent Pipe Condensate Drain Optional Standard Vertical Vent Termination To Suitable Drain...

Page 46: ...Minimum Clearance 18 inches above roof Condensate Drain Alternative Vertical Vent Termination Venting for Direct Vent Water Heater cont Alternative vertical vent termination kits are commercially avai...

Page 47: ...supplier or plumbing inspector Water Supply Connections CAUTION IMPORTANT Do not apply heat to the HOT or COLD water connections If sweat connections are used sweat tubing to the adapter before fittin...

Page 48: ...upply line and connect it to the water inlet on the water heater To ensure proper operation of the water heater follow these water pressure guidelines Operation of the water heater requires a minimum...

Page 49: ...ollowing guidelines when connecting the HOT WATER OUTLET Connections between the water heater and point s of use should be as short as possible Local codes shall govern the piping used for water conne...

Page 50: ...outlet pipe as shown above The other end of the pipe should be routed to a suitable drain to eliminate potential water damage For safe operation of the water heater be sure that The pressure rating of...

Page 51: ...et Water Inlet Water Inlet Drain Drain Condensate Drainage Be sure the condensate runs freely to a drain and does not accumulate inside the water heater In cold climates precautions may need to be tak...

Page 52: ...tallation code Apply a thin coat of pipe compound to all threaded male ends Compound must be of the type resistant to the action of LP gas To ensure proper water heater operation the gas pipe and gas...

Page 53: ...HR Therefore the cubic feet per hour 199 900 75 000 2500 109 FT3 HR If the pipe length is 100 ft then the 3 4 inch pipe size capable of supplying 197 FT3 HR of propane gas will be adequate Gas Input...

Page 54: ...gas supply line NOTICE Lever type gas shut offs should all be T handle type Using the proper size piping fittings and components build the gas supply line to the water heater NOTICE The gas supply lin...

Page 55: ...s a gas leak that must be corrected Contact a qualified service technician Pressure Testing the Gas Supply System CAUTION Install a gas pressure regulator in the gas supply line This regulator should...

Page 56: ...of the power supply cord on the outside of the water heater If local codes require hard wiring see instructions for Hard Wiring the Electrical Connections below Hard Wiring the Electrical Connections...

Page 57: ...LECTROVALVE 2 LECTROVALVE 1 SOLENOID VALVE 1 LECTROVALVE DANS ADMISSION DE GAZ SOLENOID VALVE 0 ELECTRODE ALLUMEUR ANTI FROST HEATER CHAUFFAGE ANTI GIVRE FUSIBLE 3A OVER HEAT LIMITER LIMITEUR DE SURC...

Page 58: ...ny remote control outdoors or where it can come in contact with water Avoid installing the remote control in the following areas and or conditions area exposed to heat area exposed to steam area expos...

Page 59: ...ontrol cable between the location of the remote control and the water heater Remove the remote control from the base plate Feed the remote control cable through the large center hole in the base plate...

Page 60: ...n cables from the remote control to the remote control connection terminals NOTICE The remote control wire connection terminals are not polarity sensitive Firmly tighten the terminal screws by hand Se...

Page 61: ...ating plate Make sure there is adequate air for combustion and ventilation as described on pages 37 38 or page 44 in this manual Maintain proper clearances to combustibles and noncombustibles as speci...

Page 62: ...and airtight All vent runs are properly installed Vent terminal is properly installed Maximum vent length is observed Water supply has sufficient pressure Air has been purged from the water heater and...

Page 63: ...be suitable for use with drinking water If this water heater is installed in an application intended to supply domestic hot water needs and hot water for space heating purposes do not connect the hea...

Page 64: ...power to the appliance 3 Do not attempt to light the burner by hand 4 Turn the Gas Shutoff Valve located on the outside of the unit clockwise to the OFF position 5 Wait five 5 minutes to clear out an...

Page 65: ...on the front cover of this manual Turn the gas shut off valve counterclockwise to the ON position Turn on all electric power to the water heater The water heater burner will automatically light when...

Page 66: ...he water heater by closing the shut off valves Press the UP adjustment button repeatedly until 120 F 49 C shows in the LED display Hold the UP button until the 120 on the display starts to blink NOTIC...

Page 67: ...ff the gas and water to the water heater by closing the shut off valves Press the DOWN adjustment button repeatedly until 100 F 38 C or 85 F 29 C shows in the LED display Hold the DOWN button until th...

Page 68: ...ustment button 3 times within 5 seconds The display will show 85 Turn on the gas and water to the water heater by opening the shut off valves NOTICE The maximum flow rate at 85 F 29 C is 1 3 gpm 5 0 L...

Page 69: ...ld all be in the OFF position DOWN If altitude is above 3 280 ft 1 000 m and below 6 560 ft 2 000 m change the third switch on DIP 2 to the ON position UP If altitude is above 6 560 ft 2 000 m and bel...

Page 70: ...odel and serial number of the water heater from the rating plate 2 Specify the gas type natural or LP as marked on the rating plate 3 Parts description as shown below and number of parts desired Direc...

Page 71: ...tion 1 Control Board 2 Gas Valve 3 Burner Assembly 4 Blower Motor 5 Burner Manifold 6 Gas Inlet Connector 7 Water Control Body 8 Water Inlet Connector 3 4 9 Inlet Water Filter 10 Hot Outlet Connector...

Page 72: ...72 NOTES Notes...