10
PRODUCT INFORMATION
Specifications
BRAND
157kBTUMODELS
199.9kBTUMODELS
Rheem
EcoSense
Ruud
Reliance
Paloma
CRTGH-84DV*andCRTGH-84X*
CECOH160DV*andCECOH160X*
RHCGH160DV*
CPHH-25RDV*andCPHH-25ROF*
CRTGH-95DV*andCRTGH-95X*
CECOH200DV*andCECOH200X*
CRUTGH-95DV*andCRUTGH-95X*
RHCGH200DV*
CPHH-32RDV*andCPHH-32ROF*
ApplianceType
Indoor(DV)&Outdoor(X)
Indoor(DV)&Outdoor(X)
ElectricalRating
120V/60Hz
120V/60Hz
TypeofGas*
NG
LP
NG
LP
InletGasPressure
Max.(in.ofw.c.)
10.5
13.0
10.5
13.0
InletGasPressure
Min.(in.ofw.c.)
4.0
8.0
4.0
8.0
ManifoldPressure
(
in.ofw.c.atmax.input)
2.5Indoor
2.6Outdoor
3.1
3.9Indoor
4.2Outdoor
4.6Indoor
4.7Outdoor
MaximumWaterSupplyPressure(psi)
150
150
MaximumInputRate(btu/hr)
157,000
199,900
MinimumInputRate(btu/hr)
11,000
11,000
RecoverRating(gal/hr)
178
226
ShippingWeight(lbs)
81
81
MinimumActivationFlowRate(gpm)
0.40
0.40
ExtinctionFlowRate(gpm)
0.25
0.25
HotWaterCapacity(gpm@35°Frise)
8.5
9.5
HotWaterCapacity(gpm@77°Frise)
3.9
4.9
DefaultTemperatureSetting(nocontroller)
120
120
TemperatureDefaultSetting
100
100
MinimumTemperatureSetting(°F)
85
85
EfficiencyRating(EnergyFactor)
0.94
0.94
ElectricalConsumption
Normal
100W
100W
Standby
3–5W
3–5W
AntifreezeProtection
200W
200W
VentSize(IndoorOnly)
2"or3"
2"or3"
WaterConnections
3/4"NPT
3/4"NPT
GasConnection
3/4"NPT
3/4"NPT
WaterSupplyPressure
14-150PSI
14-150PSI
HighAltitude(upto10,000ft.)
Yes
Yes
Multiple-UnitInstallation
Yes
Yes
SafetyDevices
OverheatFilmWrap,FlameRod,WaterTemperatureHigh-LimitSwitch,Flue
TemperatureHigh-LimitSwitch,PressureReliefValve
Accessories
RemoteControl,ServiceValves,VentKits,PipeCover,EZLink,MIC-6,MIC-
185,RecessBox**
*NorNG=naturalgasandPorLP=liquefiedpetroleum
**=OutdoorOnly
Product Information