RF-R586 Series Industrial Grade Cellular Router
P.H.U. RFoG Tomasz Paszkowski, ul. Starogrodzka 1/2, 72-300 Gryfice, NIP:857-115-72-13, REGON 811833063, tel. 602794466
90
1) try to check if the PPTP Status keep “on” in web status page. If sometimes “on”, and sometimes
“down”, please check the PPTP configuration is correct.
2) Check if the PPTP Server assigned remote LAN with RF-R586’s LAN IP network range. RF-R586
default LAN IP is 192.168.8.1, and submask is 255.255.255.0. Sometimes the users forget to assign
remote LAN IP 192.168.8.1 for PPTP VPN Server.
If the PPTP VPN Server’s remote LAN IP is 192.168.1.0/24 or 192.168.0.0/24, and cannot be
changed, please change RF-R586 LAN IP from 192.168.8.1 to 192.168.1.1 or 192.168.0.1, also do
not forget to manually change the RF-R586 Default Gateway to 192.168.1.1 or 192.168.0.1
meanwhile.
3) with the following steps, normally it can solve the issue. Otherwise, please contact RFoG Sales or
Support.
Summary of Contents for RF-R586 Series
Page 1: ...RF R586 Series Industrial Grade Cellular Router User Manual ...
Page 124: ......