36
5.3 Removing the Valve Assembly for
Servicing
1. Unplug the power cord.
2. Shut off water supply or put bypass valve(s) into
bypass position.
3. Remove cover and with screwdriver, relieve tank
pressure by pushing open valve No. 7 (rear flapper)
on control as shown (Figure 5.2).
Figure 5.2
4. When used with a globe valve bypass, loosen and
detach the inlet, outlet, brine and drain lines from
the valve. If using the 1265 bypass, loosen and
remove valve from bypass as well as loosening and
removing the brine and drain lines.
5. Unscrew (counterclockwise) and remove valve
from tank.
6. To replace the control valve, reverse the above
procedure.
5.4 Removing the Control
Complete the following steps to remove the 960
ProSoft control for servicing:
1. Unplug the wall-mount transformer.
2. Shut off the water supply or put the bypass valve(s)
into bypass position.
3. Remove the rear cover by depressing the two tabs
provided on the cover, Figure 5.3. Lift the front of
the cover and remove to expose the valve body.
Figure 5.3
4. Relieve system pressure by opening the Backwash
Drain Valve (the seventh valve back from the
control) with a screwdriver, Figure 5.4.
Figure 5.4
5. To remove the camshaft or to reinstall it, the arrow
on the rear of the cam shaft must be pointing at the
line on the rear “hoop” of the top plate. This occurs
when the cycle indicator is rotated to the refill
position. Press down on the back of the camshaft
to disengage it from the rear “hoop” of the top
plate, Figure 5.5.
Slide the camshaft back to disengage it from the
timer, Figure 5.6.
Figure 5.5
Tab
Reynolds Water Conditioning Co.
24545Hathaway
Farmington Hills, MI 48335
800-572-9575