Go to Section 2.2 for detailed explanation of the programming parameters on this page.
Table 3.2 - Programming Performa Cv 962F Five Cycle Filter
Parameter
Description
Range of
Values
Minimum
Increment
Recommended
Program
Value
Units of
Measure
Notes
P1
Day of week and
time of day
(1-7)
1:00-12:59
AM or PM
Metric
(1-7)
0:00-23:59
(1 day)
1 Minute
Current Day and
Time
Hour
Minute
Range depends on value selected for P13.
For day of week SUN=1, MON=2, TUE=3,
WED=4, THU=5, FRI=6, SAT=7,. THIS IS
THE LEFT MOST DIGIT ON THE DISPLAY
P2
Time of day to start
regeneration
1:00-12:59 AM
or PM
00:00-23:59
As required
Hour
Minute
Range depends on value selected for P13
P3
As recommended
10
100
P4
Potassium
Permanganate
KMnO4
.5-125.0
.2-50.0
.5
.2
As required
A potassium permanganate feeder with a float
must be used.
Number programmed into P5 equals gallons
of dissolved potassium permanganate,
multiplied by 3.
P5
Filter capacity
As required
U.S.
Metric
Divide the volumetric capacity (gallons) of the
filter by 100 and enter this number into P5.
Divide the volumetric capacity (cubic meters)
by 10 and enter this number into P5.
P6
Refill controller
2-200
1
Selected from
Table 2.2
This number tells the controller the rate of
refill based on the refill control installed. Refill
dwell time is calculated to refill the proper
amount of water into the tank.
P7
Brine draw rate
2-200
1
Selected from
Table 2.2
This number tells the controller the draw rate
based on the injector size. The dwell time in
the draw position is then calculated.
P9
Backwash time
4-60
1
20*
Minutes
*May be adjusted for application.
P10
Slow rinse time
7-125
1
50*
Minutes
*May be adjusted for application. This time
does not include the calculated brine draw
time.
P11
Fast Rinse time
2-60
1
8*
Minutes
*May be adjusted for application.
P12
Units of measure
0-1
1
0
0 = US, 1 = Metric
P13
Clock mode
0-1
1
0
0 = 12 hour clock, 1 = 24 hour clock
P14
Interval
Regeneration
(Calendar override)
0-30
1
0
Days
0 = no interval selected
P15
Reserve Type
0-3
1
0
0 = Smart Reserve, 1 = Fixed Reserve, 2 =
Smart Reserve with Immediate Regeneration,
3 = Fixed Reserve with Immediate
Regeneration.
P16
Fixed reserve
percentage
0-70
1
30
This number is used to establish the fixed
reserve. It is also used to establish the initial
Daily Average.
P17
Operation type
0-7
1
3
3 = Single or Parallel Conditioner
P18
Salt/Capacity
Change Lock out
0-1
1
0
0 = none, 1 = Salt/Capacity change locked out
P19
Flow Sensor Select
1-4
1
1
1 = 1” Autotrol Turbine, 3 = User Defined K-
factor, 2 = 2” Autotrol Turbine, 4 = User
Defined Pulse Equivalent
P20
K-factor or Pulse
Equivalent
0.00-255.00
.01
Number used for Meter K-factor or Pulse
Equivalent.
P21
Remote
Regeneration Switch
Delay
0-254
1
60
Seconds
Time remote switch must be active to start a
backwash
P22
Factory Use Only -
DO NOT CHANGE
99