4.3 Performa Cv Softener Performance Data
Table 4.1 - Performa Cv Injector Performance Chart
Injectors L - R Flow Rate Charts (gpm)
PSI
L
M
N
Q
R
Draw
Rinse
Draw
Rinse
Draw
Rinse
Draw
Rinse
Draw
Rinse
20
0.26
0.4
0.3
0.5
0.4
0.65
0.4
0.9
0.45
1.2
30
0.3
0.45
0.4
0.55
0.45
0.75
0.5
0.95
0.5
1.3
60
0.5
0.6
0.6
0.8
0.75
1
0.82
1.4
0.9
1.75
80
0.6
0.65
0.7
0.85
0.8
1.1
0.9
1.6
1
2
100
0.6
0.76
0.7
0.9
0.8
1.6
0.95
1.8
1.1
2.2
Injectors L - R Flow Rate Charts (Lpm)
Bar
L
M
N
Q
R
Draw
Rinse
Draw
Rinse
Draw
Rinse
Draw
Rinse
Draw
Rinse
1.4
0.98
1.5
1.1
1.9
1.5
2.5
1.5
3.4
1.7
4.5
2.1
1.1
1.7
1.5
2.1
1.7
2.8
1.9
3.6
1.9
4.9
4.2
1.9
2.3
2.3
6
2.8
3.8
3.1
5.3
3.4
6.6
5.6
2.3
2.5
2.6
3.2
3
4.2
3.4
6
3.8
7.6
7
2.3
2.9
2.6
3.4
3
4.9
3.6
6.8
4.2
8.3
Table 4.2 - Service and Backwash Flow Performance Data
Flow vs Pressure Drop (gpm)
Flow vs Pressure Drop (Lpm)
PSI
Service (Cv 6.5)
Backwash (Cv 4.0)
Bar
Service (Cv 6.5)
Backwash Cv 4.0)
5
15
9
0.35
56
34
10
20
13
0.7
76
49
15
25
16
1
95
61
20
29
18
1.4
109
68
25
32
20
1.7
121
76
30
35
22
2.1
132
83
Table 4.3 - Recommended Drain Flow Controls (Backwash Anion and Cation Resin @ 55
°
F (12.7
°
C) Water
Temperature
Tank Diameter
Inches (mm)
Bed Area
sq. ft.
Anion Resin @ 3 gpm/sq ft
(m
3
h/sq ft)
Cation Resin @ 5 gpm/sq
ft
(m
3
h/sq ft)
14 (35.6)
1.02
3 (.7)
5 (1.1)
16 (40.6)
1.38
4 (.9)
7 (1.5)
18 (45.7)
1.76
5 (1.1)
8 (1.8)
21 (53.3)
2.4
7 (1.5)
12 (2.7)
Reynolds Water Conditioning Co.
24545Hathaway
Farmington Hills, MI 48335
800-572-9575