Connect or disconnect plug connections only in de-energized, dry and
clean state.
●
Protect the flange sockets from external force effect.
When motors in ATEX design are used:
Connect an additional protective conductor connection ac‐
cording to the Operating Instructions DOK-MOTOR*-
IDYN*A*EXPD-IB□□-□□-P.
①
Flange socket INS480 (view on the plug-in side)
②
Flange socket INS380 (view on the plug-in side)
③
Coupling
④
Flange socket
⑤
Only one PTC sensor is applied (spare sensor lines are provided in
the socket housing)
⑥
Holding brake (optional)
⑦
Overall shield connection by clamping the strain relief cable in the
socket
⑧
Connection designations on the Rexroth drive controller
Fig.6-5:
Line connection via flange socket; connection diagram
●
Ensure the line cross-section required for connecting the
particular motor specified in the Project Planning Manual
Rexroth IndraDyn A.
●
Use ready-made Rexroth connection cables; see documen‐
tation
Rexroth Connection Cables IndraDrive and Indra‐
Dyn.
DOK-MOTOR*-MAD/MAF****-IT01-EN-P
Rexroth IndraDyn A Asynchronous Motors MAD / MAF
Bosch Rexroth AG
37/67
Assembly