ing to the outlet direction specified by the user. If necessary, the cable outlet
direction can be re-adjusted at the terminal box.
Proceed as follows when connecting the power cable to the terminal box:
1.
Open the cover of the terminal box ①.
Unscrew and remove the mounting screws (4 screws).
①
Cover
②
Seal
③
Terminal block U-V-W
④
PE connection
⑤
O-ring
⑥
Adapter plate fastening screws
⑦
Protection cover of cable gland connecting thread
⑧
Adapter plate for cable screwing
⑨
Terminal strip (brake, temperature sensor)
⑩
Purge gas connection (only for motors in ATEX design)
⑪
Terminal screws for setting the cable outlet direction (4x)
Fig.6-9:
Terminal box (options "D, E, G, H").
2.
Check the cable outlet direction and rotate the terminal box if necessary.
●
Detach the terminal box.
Unscrew the mounting screws ⑪ and rotate the terminal box by 90
to no more than 180 degrees to achieve the desired outlet direc‐
tion.
●
Fasten the terminal box.
Screw in and tighten the mounting screws ⑫.
Screw tightening torque ⑪: 6.5 Nm (±10 %)
⇒ There is a seal between the terminal box and the motor housing. After
rotating and before re-tightening the terminal box, check the seal to en‐
sure its proper condition and correct positioning.
3.
Unscrew the protection cover of the screwed cable gland ⑦.
4.
Detach the adapter plate ⑧ from the terminal box.
5.
Tightly screw the adapter plate to the metric cable gland at the power
cable.
Bosch Rexroth AG
DOK-MOTOR*-MAD/MAF****-IT01-EN-P
Rexroth IndraDyn A Asynchronous Motors MAD / MAF
40/67
Assembly