![REXROTH efc series Instruction Manual Download Page 58](http://html1.mh-extra.com/html/rexroth/efc-series/efc-series_instruction-manual_1449615058.webp)
Bit
Name
Function
15...12 Network Status Red LED
15..5 = Reserved
4 = Steady On
3 = Blink 4 Hz
2 = Blink 2 Hz
1 = Blink 1 Hz
0 = Off
11...8 Network Status Green LED
7...4 Module Status Red LED
3...0 Module Status Green LED
Tab. 10-4: Parameter H3.18
●
H3.34 MEP: Communication Platform State
This parameter describes the internal communication platform state.
Value
State
Description
0
NOP
Communication platform inactive
1
START
Running boot process
2
STARTERR
Error at boot process
3
SYSRDY
System up, preparing for configuration
4
CONFIG
System basic configuration done
5
CFGERR
Error at system basic configuration
6
COMCFG
Fieldbus selection done
7
COMCFGERR
Error at fieldbus selection
8
COMINIT
Ready for being connected by fieldbus master
9
COMINITERR
Error at fieldbus configuration
10
COMRDY
Preparing for cyclic communication
11
COMACTV
Cyclic communication active
12
COMERR
Error / Breakdown of cyclic communication
13
UPDATE
Update in progress
Tab. 10-5: Parameter H3.34
●
H3.35 MEP: Communication Diagnosis Flags
This parameter gives some detailed diagnosis on internal events. However, all
diagnosis flags are assigned to some error codes and corresponding display
messages.
Bit
Name
Description
31...28 -
Reserved
27
Host Watchdog
Internal communication to base system timed out.
26
FW CRC-Error
Communication Platform Firmware consistency check failed.
25...18 -
Reserved
Bosch Rexroth AG
Parameters
Multi-Ethernet Card
52/61
DOK-RCON0*-XFCX610*MUL-IT02-EN-P
Summary of Contents for efc series
Page 1: ...Frequency Converter Multi Ethernet Card Instruction Manual R912006860 Edition 02 ...
Page 6: ...Bosch Rexroth AG Multi Ethernet Card IV DOK RCON0 XFCX610 MUL IT02 EN P ...
Page 65: ...Multi Ethernet Card Bosch Rexroth AG DOK RCON0 XFCX610 MUL IT02 EN P 59 61 ...
Page 66: ...Bosch Rexroth AG Multi Ethernet Card 60 61 DOK RCON0 XFCX610 MUL IT02 EN P ...