4-78
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200
ECODRIVE03 Drive Controllers
Signal allocation to the actual position value
Signal allocation
(X8)
signal designation
signal form
actual position value
(with default setting)
G2Sin+(A+)
G2Sin- (A-)
G2Cos+(B+)
G2Cos- (B-)
G2Ref+(R+)
G2Ref- (R-)
sine (1Vss)
without absolute value
(e.g. gearwheel encoder)
reducing
G2Sin+(A+)
G2Sin- (A-)
G2Cos+(B+)
G2Cos- (B-)
G2Ref+(R+)
G2Ref- (R-)
square (TTL)
without absolute value
reducing
G2Sin+(A+)
G2Sin- (A-)
G2Cos+(B+)
G2Cos- (B-)
sine (1 V
ss
)
with absolute value
(e.g. EnDat)
increasing
Fig. 4-119: Signal allocation to the actual position value