ECODRIVE03 Drive Controllers
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200
4-95
XE1, XE2 Protective conductor connections for motor and mains
Technical description of connector
See page 4-40: "A look at the drive controller and connector
designations".
Type
No. of pins
Design
screw-in connection
1
screw-in connection for
ring terminals M5
Fig. 4-155: Design
min. tightening torque
[Nm]
max. tightening torque
[Nm]
0
.
3
5
.
2
Fig. 4-156: Tightening torque
Cross section
single wire
[mm ²]
Max. connectable
cross section
in mm ²
Max. cross section
in AWG
gauge no.:
-
-
5
2
-
-
Fig. 4-157: Connection cross section
XE1, Protective conductor connection for motor
See page 4-64: "Motor connection".
XE2, Protective conductor connection for mains
Note:
PE connection > 10 mm ²
Reason:
high
leakage
currents
(EN
50178/1998,
section: 5.3.2.1)
Illustration:
Design:
Tightening torque:
Connection cross section:
|
(479) 422-0390