4-124
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200
ECODRIVE03 Drive Controllers
Ap5184f1.fh7
R1
C1
Q
n
I
out
Schematics
R1: 20k
C1: no data
Fig. 4-217: Output circuit
Output voltage:
High
Low
min.
16 V
-0.5 V
max.
U
ext
1.5 V
Output current I
out
80 mA
s
n
0
0
6
<
t
u
o
b
a
e
m
it
p
o
r
d
d
n
a
e
s
ir
overload protection
- short circuit protection;
at I
out
> 300 mA outputs switch off
- thermal off
Fig. 4-218: Outputs
Pin
Inputs
Pin
Outputs
1
I 0
Parameter
17
Q 0
Hand
2
I 1
Hand / Auto
18
Q 1
Auto
3
I 2
Start
19
Q 2
Error
4
I 3
STOP
20
Q 3
Run
5
I 4
Jog+
21
Q 4
Output 01
6
I 5
Jog-
22
Q 5
Output 02
7
I 6
Input 01
23
Q 6
Output 03
8
I 7
Input 02
24
Q 7
Output 04
9
I 7
Input 03
25
Q 8
Output 05
10
I 9
Input 04
26
Q 9
Output 06
11
I 10
Input 05
27
Q 10
Output 07
12
I 11
Input 06
28
Q 11
Output 08
13
I 12
Input 07
14
I 13
Input 08
15
I 14
Input 09
16
I 15
Input 10
Fig. 4-219: Default allocation of the inputs and outputs
Note:
Inputs 01 ... 10 and Output 01 ... 08 can be configured.
Output circuit connection Q 0
–
Q 11:
Output connection
Q 0 – Q 11:
Default allocation of binary I/Os:
|
(479) 422-0390
Summary of Contents for BZM 01.3-01-07
Page 343: ......