4-38
ECODRIVE03 DKC**.040, DKC**.100, DKC**.200
ECODRIVE03 Drive Controllers
DKC**.3-200-7
0
100
200
300
400
500
600
0
2000
4000
6000
8000
10000
12000
P
ZWD
[W]
U
N
3
[V
]
—————
:
DKC**.3-200-7, 60 Hz without CZM
— — — —
:
DKC**.3-200-7, 60 Hz with CZM
Fig. 4-39:
DC bus continuous power in single-phase mode with 60 Hz
Note:
Do not operate DKC**.3-200-7s with single-phase mains with
smoothing choke !
|