![Resfab CR-40F Instruction Manual Download Page 30](http://html.mh-extra.com/html/resfab/cr-40f/cr-40f_instruction-manual_1443718030.webp)
Resfab Equipment Inc.
CR-40F & CR-60F
Note:
If not using the buzzer option, the menu 1 setting is completed. Press the
IDLE
TWO TEMP
key to confirm the menu setting.
If
using the buzzer option
, press the
DOWN
arrow to get to next step, buzzer setting.
Step 4-
Setting the alarm:
The word
alarm
will blink on the screen. Press the
IDLE ONE
TEMP
key to chose / modify at what step of the cooking cycle the buzzer should sound.
Using the
UP
and
DOWN
arrows, chose between
nonE, Stir, Add, ALert.
If the choice
is
nonE
, there won't be any buzzer. Set the choice by pressing the
IDLE TWO TEMP
key
.
Press the
DOWN
arrow to choose when (number of minutes from the end of the
cooking cycle) the buzzer will sound. On the screen, letters
ATinE
will blink. Press the
IDLE ONE TEMP
key to chose / modify the time. Using the
UP
or
DOWN
arrow,
select the time (example 5:00). Press the
IDLE TWO TEMP
key to confirm the choice.
Setting is completed.
Press again on the
IDLE TWO TEMP
key to confirm the setting
of
menu #1.
Step 5-
Visualizing the menu setting:
At the same time press the
UP
and
DOWN
arrows for
5 seconds
. A number (from 1 to
40) will display. Using the
UP
or
DOWN
arrows, chose to menu to be visualized.
Access the setting mode by pressing the
IDLE ONE TEMP
key.
First will be displayed the cooking temperature (
StPt 1
and the
temperature
). Press the
DOWN
arrow and will display (
timE 1
and
cooking time
).
Press the
DOWN
arrow and will display
at which step
the buzzer will sound.
Press the
DOWN
arrow and will display when (
minutes of the end of the cycle
) the
buzzer will sound.
Press the
IDLE TWO TEMP
key to return to menu 1, ready for cooking.
Press the
MENU SELECT
key for 5 seconds to return to the beginning.
TO PROGRAM A NEW MENU, RETURN TO STEP 1
Summary of Contents for CR-40F
Page 17: ...Resfab Equipment Inc CR 40F CR 60F 4 3 1 2 8 9 12 13 14 7 6 5 10 11 ...
Page 19: ...Resfab Equipment Inc CR 40F CR 60F 15 16 17 18 ...
Page 21: ...Resfab Equipment Inc CR 40F CR 60F Not identified Not identified 19 20 21 23 22 24 25 27 26 ...
Page 23: ...Resfab Equipment Inc CR 40F CR 60F 14493 Carrying handle 74103 Filter O ring 29 28 ...
Page 24: ...Resfab Equipment Inc CR 40F CR 60F ELECTRIC DIAGRAM CR 40F ELECTRONIC TIMER ...
Page 25: ...Resfab Equipment Inc CR 40F CR 60F ELECTRIC DIAGRAM CR 40F MULTI PROGRAM CONTROLLER ...
Page 26: ...Resfab Equipment Inc CR 40F CR 60F ELECTRIC DIAGRAMME CR 60F ELECTRONIQUE TIMER ...
Page 27: ...Resfab Equipment Inc CR 40F CR 60F ELECTRIC DIAGRAMME CR 60F MULTI PROGRAM CONTROLLER ...