Blower Housing can rotate CW or
CCW as shown in these views.
Blower Housing
Band Clamp Loop
1” Loop to Loop
Band Clamp
Hex Nut
Detail A
Blower Housing Rotational Procedures:
(May be performed by untrained personnel)
1. Loosen hex nut on band clamp using 3/8 inch (9.52 mm) nut driver.
2. Rotate blower housing to desired position, then hand tighten hex nut
until band clamp loops are 1 inch (25.4 mm) apart.