800.847.0380
www.republic-mfg.com
35
In order to remove or replace the Belt, the Tension Block Assembly must be rotated out of the way to allow for the Tension Arm to
swing (CW). Loosen the 5/16-18 SHCS as shown in Figure 1, the screw is located on the backside of the Mounting Plate. Use a 1/4
inch (6.35 mm) allen wrench (not shown) on the 5/16-18 SHCS.
Once the 5/16-18 SHCS is removed, rotate the Tension Block (CCW) to allow for the Tension Arm to swing (CW) as shown in Detail
B.
Note: The same belt removal and installation procedure applies for the RB2400 model with one exception–there are two (2) belts.
Tension Arm
Figure 1
Detail B
Tension Block rotated
counterclockwise (CCW)
(Tension Pulley removed for clarity)
Figure 2
RB800/RB1200HC/RB2000/RB2400 Belt Replacement Procedure
Summary of Contents for RB-SERIES
Page 24: ...www republic mfg com 800 847 0380 24 RB2000 Exploded View ...
Page 52: ...www republic mfg com 800 847 0380 52 340 1035 RB2000 Stainless Steel Inlet Filter Assembly ...
Page 53: ...800 847 0380 www republic mfg com 53 340 2070 340 2071 RB4000 RB4002 Inlet Filter Assembly ...
Page 56: ...www republic mfg com 800 847 0380 56 RB800 1200HC Low Profile Enclosure Enclosures ...
Page 59: ...800 847 0380 www republic mfg com 59 RB4000 Painted Aluminum Enclosure ...