98
4.4.20
Maintenance
This menu is accessed by pressing the
‘MAINTENANCE’ button in the main menu (see Figure
4.41)
This screen gives you access to several menus, and functions.
Night position:
= The die sets close and the temperature goes to 30°C. to prevent
condensation and cleaning water in the die sets (use this function
after production). Can also be activated in the Operator submenu
(see Paragraph 4.3.1)
Flush gas system:
=
This function opens the gas valve to flush the gas tank (use this
function when the gas tank has been disconnected).
Cleaning chain:
= This function activates the chain cleaning program (this is a
option).
Bleeding lubrication:
= By pressing this button it repeatedly activates the chain lubrication
cycle to get rid of air in the oil tubes.
Press button
return
and the screen goes back to the Main Menu.
Figure 4.41 Maintenance