64
4.2.3 Switching functions
The buttons in group D (see Figure 4.8.) are similar to main switches.
A number of functions such as adding gas to a package or automatic filling can be turned on
and off centrally here. Some functions can only be switched on if the packaging program
chosen permits this, so that a function cannot be switched on unintentionally. The functions of
the buttons are shown in table 3:
Table 3 Button functions
Button
Name
Function
Heating
Switches the heating elements in the
forming and sealing stations.
Pumps and
motors
Starts and stops the internal vacuum pump.
Transport once
Transports the film one stroke length
further. All other systems are deactivated.
This function can be applied only if the
Automatic function is switched off.
Gas Flush
Switches on or off the insertion of gas into
the packaging. (This only functions if the
packaging program chosen supports it.)
Plug assist
Plug assist in forming station can be turned
on and off with this button.
Marking detection Here the photocell has to be switched on for
packaging with printed top film. This only
functions on a machine fitted with a
photocell and a film brake.
Cross cutter
This button is used to turn the cross cutter
on and off for all programs.
Filler
If the machine is connected up to an
automatic filler, the filler can be turned on
and off with this button.
External labellers on the machine can be
turned on and off with this button.
Date coder
External coder on the machine can be
turned on and off with this button
Manual mode
This button is turned on when the machine
is being manually operated, such as during
washing or lubricating the chain.
Figure 4.8 Switching functions