889-2106-03
Model U-1400 Operations Manual Rev Apr 2020 Page
22
of 39
P
ARAMETER
.............................Firmware Version and Revision.
S
ETTINGS
..................................View Only.
S
ETTING
D
ISPLAYED
................View Only.
7-
SEGMENT
D
ISPLAY
................Model letter and firmware version on
one screen and revision on the other.
The display will toggle between the
two screens with a 50% duty cycle.
D
EFAULT
S
ETTING
....................Not Applicable.
E
XAMPLE
..................................Model U-1400 firmware version 4,
revision .00.
5.2.1
PRIMARY VITAL OUTPUT MAPPING SCREENS
P
ARAMETER
...................Primary Vital Output Mapping.
S
ETTINGS
........................256 selections - any and all combinations of the four Loop
Status Inputs and the four Vital Inputs.
S
ETTING
D
ISPLAYED
......Bargraph indicates Loop Status Inputs and/or Vital Inputs
mapped to the Primary Vital Outputs. In Loop Status Input
mode, the leftmost segment = Loop Status Input 4, next
segment = Loop Status Input 3, next segment = Loop Status
Input 2, next segment = Loop Status Input 1. In Vital Input
mode, the center four segments are used. The leftmost center
segment = Vital Input 4, next segment = Vital Input 3, next
segment = Vital Input 2, next segment = Vital Input 1. The
loop symbol indicates which Primary Vital Output the Loop
Status Inputs and/or Vital Inputs are being mapped to.
7-
SEGMENT
D
ISPLAY
......7-segment display will show currently selected setting. The
first character corresponds to the Loop Status Inputs mapped to
the Primary Vital Outputs, the second character corresponds to
the Vital Inputs mapped to the Primary Vital Outputs.
D
EFAULT
S
ETTINGS
........Primary Vital Output 1 = 00. No Loop Status Inputs mapped to
Primary Vital Output 1. No Vital Inputs mapped to Primary
Vital Output 1.
Primary Vital Output 2 = 00. No Loop Status Inputs mapped to Primary Vital Output 2.
No Vital Inputs mapped to Primary Vital Output 2.
Primary Vital Output 3 = 00. No Loop Status Inputs mapped to Primary Vital Output 3.
No Vital Inputs mapped to Primary Vital Output 3.
Primary Vital Output 4 = 00. No Loop Status Inputs mapped to Primary Vital Output 4.
No Vital Inputs mapped to Primary Vital Output 4.
E
XAMPLE
........................Loop Status Inputs 1, 2, & 3 mapped to Primary Vital Output 1.
No Vital Inputs mapped to Primary Vital Output 1.
N
OTES
.............................The characters are displayed in Hexadecimal notation (Base
16).
When viewing and/or setting the Primary Vital Output mapping
settings, use the FUNC pushbutton to advance to the mapping
settings of the next Primary Vital Output.
A Primary Vital Output is deactivated if no Loop Status Inputs
or Vital Inputs are mapped to it.
1
©
©
1
©