889-2106-03
Model U-1400 Operations Manual Rev Apr 2020 Page
23
of 39
To set the mapping status of the Loop Status Inputs, repeatedly press the
FUNC
pushbutton to enter Program
Mode and toggle through the set-up parameters until the display screen shows the bargraph and two of the seven-
segment display characters. The left character and a loop symbol will flash indicating the current setting and the
four leftmost bargraph segments will show the corresponding Loop Status Input mapping. Use the
(UP) or
(DOWN) pushbutton to change the setting to the desired configuration. Use the
FUNC
pushbutton to advance to
the next Primary Vital Output (indicated by a flashing numbered loop symbol at the bottom of the LCD screen).
The various combinations of display characters and bargraph display are shown below.
Any Input on Loops 3, 2, or 1 will be
mapped to the Primary Vital Output.
Any Input on Loops 3 or 2 will be
mapped to the Vital Output.
Any Input on Loops 3 or 1 will be
mapped to the Primary Vital Output.
Any Input on Loop 3 will be mapped to
the Primary Vital Output.
Any Input on Loops 2 or 1 will be
mapped to the Primary Vital Output.
Any Input on Loop 2 will be mapped to
the Primary Vital Output.
Any Input on Loop 1 will be mapped to
the Primary Vital Output.
No Loop Inputs will be mapped to the
Primary Vital Output.
Display Setting
Loop Status Inputs elected
Any Input on Loops 4, 3, 2, or 1 will be
mapped to the Primary Vital Output.
Any Input on Loops 4, 3, or 2 will be
mapped to the Primary Vital Output.
Any Input on Loops 4, 3, or 1 will be
mapped to the Primary Vital Output.
Any Input on Loops 4 or 3 will be
mapped to the Primary Vital Output.
Any Input on Loops 4, 2, or 1 will be
mapped to the Primary Vital Output.
Any Input on Loops 4 or 2 will be
mapped to the Primary Vital Output.
Any Input on Loops 4 or 1 will be
mapped to the Primary Vital Output.
Any Input on Loop 4 will be mapped to
the Primary Vital Output.
3
4
1
2