To set the mapping status of the Health Status Inputs when in the Auxiliary Vital Output Mapping Program Mode,
press the
CHAN
pushbutton once again. The right character and a loop symbol will flash indicating the current
setting and the four rightmost bargraph segments will show the corresponding Health Status Input mapping. Use
the
(UP) or
(DOWN) pushbutton to change the setting to the desired configuration. Use the
FUNC
pushbutton to advance to the next Auxiliary Vital Output (indicated by a flashing numbered loop symbol at the
bottom of the LCD screen). The various combinations of display characters and bargraph display are shown
below.
When in Normal Mode, repeatedly press the
FUNC
pushbutton to enter Program Mode and toggle through the set-
up parameters until the display screen shows the bargraph and three of the seven-segment display characters. The
left character and a loop symbol will flash indicating the current setting and the four leftmost bargraph segments
will show the corresponding Vital Input mapping. Press the
CHAN
pushbutton twice. The right character and a
loop symbol will flash indicating the current setting and the four rightmost bargraph segments will show the
corresponding Health Status Input mapping. Use the
(UP) or
(DOWN) pushbutton to change the setting to
the desired configuration. Use the
FUNC
pushbutton to advance to the next Auxiliary Vital Output (indicated by a
flashing numbered loop symbol at the bottom of the LCD screen). The various combinations of display characters
and bargraph display are shown below.
Display Setting
Health Status Inputs
Selected
Any Input on Health Status 4, 3, 2, or 1
will be mapped to the Auxiliary Vital
Any Input on Health Status 4, 3, or 2
will be mapped to Auxiliary Vital
Any Input on Health Status 4, 3, or 1
will be mapped to the Auxiliary Vital
Any Input on Health Status 4 or 3 will
be mapped to the Auxiliary Vital
Any Input on Health Status 4, 2, or 1
will be mapped to the Auxiliary Vital
Any Input on Health Status 4 or 2 will
be mapped to the Auxiliary Vital
Any Input on Health Status 4 or 1 will
be mapped to the Auxiliary Vital
Any Input on Health Status 4 will be
mapped to the Auxiliary Vital Output.
3
4
1
2
Any Input on Health Status 3, 2, or 1
will be mapped to the Auxiliary Vital
Any Input on Health Status 3 or 2 will
be mapped to the Auxiliary Vital
Any Input on Health Status 3 or 1 will
be mapped to the Auxiliary Vital
Any Input on Health Status 3 will be
mapped to the Auxiliary Vital Output.
Any Input on Health Status 2 or 1 will
be mapped to the Auxiliary Vital
Any Input on Health Status 2 will be
mapped to the Auxiliary Vital Output.
Any Input on Health Status 1 will be
mapped to the Auxiliary Vital Output.
No Health Status Inputs will be
mapped to the Auxiliary Vital Output.