889-2106-03
Model U-1400 Operations Manual Rev Apr 2020 Page
21
of 39
P
ARAMETER
...................Option 8 (Inductive Island Circuit).
S
ETTINGS
........................ON or OFF.
S
ETTING
D
ISPLAYED
......The word ON or OFF will be displayed.
7-
SEGMENT
D
ISPLAY
......The number of this option.
D
EFAULT
S
ETTING
..........OFF for all loop inputs.
E
XAMPLE
........................Option 8 is turned OFF for all channels.
N
OTES
.............................This option is a detector wide setting. Changing it for one
channel changes it for all channels. Turning ON Option 8
automatically turns OFF Option 9.
P
ARAMETER
...................Option 9 (Inductive Shunt Enhancement Circuit).
S
ETTINGS
........................ON or OFF.
S
ETTING
D
ISPLAYED
......The word ON or OFF will be displayed.
7-
SEGMENT
D
ISPLAY
......The number of this option.
D
EFAULT
S
ETTING
..........OFF for all loop inputs.
E
XAMPLE
........................Option 9 is turned OFF for channels 1 and 2.
N
OTES
.............................This is a paired channel option. Channel 1 is paired with
channel 2 and Channel 3 is paired with channel 4. Changing
the setting for one channel also changes the setting for the
paired channel. Turning ON Option 9 automatically turns OFF
Option 8.
P
ARAMETER
...................Primary Vital Output Delay.
S
ETTINGS
........................256 selections - 00.0 to 25.5 Seconds in 0.1 second steps.
S
ETTING
D
ISPLAYED
......7-segment display will show currently selected setting. Loop
symbol indicates which Primary Vital Output the Delay time
applies to.
7-
SEGMENT
D
ISPLAY
......Currently selected Delay time in seconds.
D
EFAULT
S
ETTING
..........00.0 seconds.
E
XAMPLE
........................Delay of 10 seconds selected for Primary Vital Output 1.
N
OTES
.............................If the loop input’s detection zone is occupied when this
parameter is changed, it will not take effect until the detection
zone is empty or the loop input is reset.
When viewing and/or setting the Primary Vital Output Delay
time settings, use the CHAN pushbutton to advance to the
Delay time settings of the next Primary Vital Output.
P
ARAMETER
...................Primary Vital Output Extension.
S
ETTINGS
........................256 selections - 00.0 to 25.5 Seconds in 0.1 second steps.
S
ETTING
D
ISPLAYED
......7-segment display will show currently selected setting. . Loop
symbol indicates which Primary Vital Output the Extension
time applies to.
7-
SEGMENT
D
ISPLAY
......Currently selected Extension time in seconds.
D
EFAULT
S
ETTING
..........00.0 seconds.
E
XAMPLE
........................Extension of 2.5 seconds selected for Primary Vital Output 1.
N
OTES
.............................If the loop input’s detection zone is occupied when this
parameter is changed, it will not take effect until the detection
zone is empty or the loop input is reset.
When viewing and/or setting the Primary Vital Output
Extension time settings, use the CHAN pushbutton to advance
to the Extension time settings of the next Primary Vital Output.
P
ARAMETER
...................Loop Fail.
S
ETTINGS
........................Pressing the
(UP) or
(DOWN) pushbutton will clear the
Loop Fail memory.
S
ETTING
D
ISPLAYED
......View only.
7
S
EGMENT
D
ISPLAY
......Loop Failures since the last time it was cleared manually or due
to power failure.
D
EFAULT
S
ETTING
..........000.
E
XAMPLE
........................There are 8 Loop Failures in the accumulator for channel 1.
N
OTES
.............................Count will be reset to 0 after loss of power, pressing the
(UP) or
(DOWN) pushbutton, or a reset input to the Reset
terminal on the motherboard.
DELAY
SECONDS
©
1
EXTENSION
SECONDS
©
1
LOOP FAIL
1
©
OPTION
OFF
1
©
OPTION
OFF
1
©