889-2106-03
Model U-1400 Operations Manual Rev Apr 2020 Page
19
of 39
P
ARAMETER
...................Sensitivity.
S
ETTINGS
........................12 selections - 1 to 10, OFF, or CALL.
S
ETTING
D
ISPLAYED
......7-segment display will show currently selected setting.
7-
SEGMENT
D
ISPLAY
......Currently selected Sensitivity.
D
EFAULT
S
ETTING
..........6 for all loop inputs.
E
XAMPLE
........................Sensitivity 6 is selected for loop input 1.
N
OTES
.............................Changing the sensitivity will reset the loop input. The bargraph
will show strength of vehicle calls so that correct sensitivity can
be verified from this screen.
P
ARAMETER
...................Option 1 (Loop/Lead-In Inductance Display).
S
ETTINGS
........................ON or OFF.
S
ETTING
D
ISPLAYED
......The word ON or OFF will be displayed.
7-
SEGMENT
D
ISPLAY
......The number of this option.
D
EFAULT
S
ETTING
..........OFF for all loop inputs.
E
XAMPLE
........................Option 1 is turned ON for all loop inputs.
N
OTES
.............................This option is a detector-wide setting. Changing it for one loop
input changes it for all loop inputs. This option will
automatically turn off in 15 minutes.
P
ARAMETER
...................Option 2 (Percentage of Inductance change, -
∆
L/L).
S
ETTINGS
........................ON or OFF.
S
ETTING
D
ISPLAYED
......The word ON or OFF will be displayed.
7-
SEGMENT
D
ISPLAY
......The number of this option.
D
EFAULT
S
ETTING
..........OFF for all loop inputs.
E
XAMPLE
........................Option 2 is turned OFF for all loop inputs.
N
OTES
.............................This option is a detector-wide setting. Changing it for one loop
input changes it for all loop inputs. This option will
automatically turn off in 15 minutes.
P
ARAMETER
...................Option 3 (Noise Filter).
S
ETTINGS
........................Four selections - 3.00 to 3.03.
S
ETTING
D
ISPLAYED
......The word ON or OFF will be displayed.
7-
SEGMENT
D
ISPLAY
......The number of this option.
D
EFAULT
S
ETTING
..........3.00 (OFF) for all loop inputs.
E
XAMPLE
........................Option 3.02 is turned ON for loop input 1.
N
OTES
.............................This option is a channel specific setting. Changing it for one
loop input changes it for that loop input only.
It is strongly
recommended that this option be set to 3.00 (OFF) for normal
operation.
P
ARAMETER
..................... Option 4 (Detection Zone Tracking).
S
ETTINGS
........................Ten selections - 4.00 to 4.08 and 4.10.
S
ETTING
D
ISPLAYED
......The word ON or OFF will be displayed.
7-
SEGMENT
D
ISPLAY
......The number of this option.
D
EFAULT
S
ETTING
..........4.02 (ON) for all loop inputs.
E
XAMPLE
........................Option 4.03 is turned ON for loop input 1.
N
OTES
.............................This option is a loop input specific setting. Changing it for one
loop input changes it for that loop input only.
SENSITIVITY
1
©
OPTION
1
ON
©
OPTION
OFF
1
©
OPTION
1
ON
©
OPTION
1
ON
©