889-2106-03
Model U-1400 Operations Manual Rev Apr 2020 Page
20
of 39
P
ARAMETER
..................... Option 5 (Sensitivity Boost).
S
ETTINGS
........................Five selections - 5.00 to 5.04.
S
ETTING
D
ISPLAYED
......The word ON or OFF will be displayed.
7-
SEGMENT
D
ISPLAY
......The number of this option.
D
EFAULT
S
ETTING
..........5.00 (OFF) for all loop inputs.
E
XAMPLE
........................Option 5.04 is turned ON for loop input 1
N
OTES
.............................This option is a loop input specific setting. Changing it for one
loop input changes it for that loop input only.
The sensitivity boost feature works in conjunction with the sensitivity setting. The
maximum sensitivity level obtainable with or without
sensitivity boost is level 10. If the setting of either sensitivity
or sensitivity boost is such that the resultant sensitivity level is
greater than 10 (e.g. Sensitivity Level 7, Sensitivity Boost
setting of 5.4), the audible detect signal (buzzer) will sound to
provide an indication that the combination being selected is
invalid. (See Section 2.2 - Sensitivity for more details.)
P
ARAMETER
..................... Option 6 (Audible Detect).
S
ETTINGS
.......................... ON or OFF.
S
ETTING
D
ISPLAYED
........ The word ON or OFF will be displayed.
7-
SEGMENT
D
ISPLAY
........ The number of this option.
D
EFAULT
S
ETTING
............ OFF for all loop inputs.
E
XAMPLE
.......................... Option 6 is turned ON for loop input 1.
N
OTES
............................... This option is mutually exclusive with the same option in any
other loop input. Turning it on for one loop input turns it off
for all other loop inputs. This option will automatically turn
off after 15 minutes.
P
ARAMETER
..................... Loop Check Timer setting.
S
ETTINGS
.......................... 256 selections - 000 to 255 minutes in 1 minute steps.
S
ETTING
D
ISPLAYED
........ 7-segment display will show currently selected setting.
7-
SEGMENT
D
ISPLAY
........ Currently selected time in minutes.
D
EFAULT
S
ETTING
............ Five minutes (005) for all loop inputs.
E
XAMPLE
.......................... The Loop Check Timer for Loop 1 is set for 25 minutes.
N
OTES
............................... This option is a loop input specific setting. Changing it for
one loop input changes it for that loop input only.
P
ARAMETER
.............................Detector ID setting.
S
ETTINGS
..................................256 selections - 000 to 255.
S
ETTING
D
ISPLAYED
................7-segment display will show currently
selected setting.
7-
SEGMENT
D
ISPLAY
................Current Detector ID setting. The
display will toggle between the two
screens with a 50% duty cycle.
D
EFAULT
S
ETTING
....................255.
E
XAMPLE
..................................Detector ID is set as 158.
N
OTES
.......................................When set to Detector ID number 255,
the detector is considered
uninitialized.
P
ARAMETER
...................Option 7 (Synch Feature).
S
ETTINGS
........................Three selections - 7.00 to 7.02.
S
ETTING
D
ISPLAYED
......The word ON or OFF will be displayed.
7-
SEGMENT
D
ISPLAY
......The number of this option.
D
EFAULT
S
ETTING
..........7.00 (OFF) for all loop inputs.
E
XAMPLE
........................Option 7 is turned OFF.
N
OTES
.............................This option is a detector-wide setting. Setting Option 7 to 7.01
activates Series Synch (SYS), setting Option 7 to 7.02 activates
Parallel Synch (SYP).
OPTION
1
ON
©
OPTION
1
ON
©
©
©
LOOP FAIL
SCANNING
1
©
OPTION
OFF
©