8
SOFTWARE INSTALLATION & SETUP
Iconyx steerable column loudspeakers are digitally controlled and a PC with appropriate software is needed during installation and setup.
Once the setup is completed the PC is no longer needed unless the system parameters need to be adjusted or changed.
The Iconyx software requires a PC meeting at least the following basic requirements:
Processor Speed:
800 MHz Pentium or higher
Memory:
256 MB or higher
Interface:
At least one available USB port compliant with USB1.1
Operating System:
Windows 2000 SP4 , Windows XP SP1 or higher, or Vista
Operating System Add-Ons: NET Framework (provided with the Iconyx software)
Screen Resolution:
1024 x 768 or higher
Browser:
Internet Explorer v5.0 or higher
Note that Windows 95 and Windows 98 are not supported.
A typical system layout is shown below.
Notes:
1. The audio cable is a conventional twisted-pair shielded audio cable. It terminates in a 3-pin Phoenix connector and loops from column
to column; looping Phoenix connectors are provided on each column. 1.0 V is required for rated power output.
2. Since the Iconyx digital network uses a RS422 serial line for control, a USB to RS422 converter/adapter (Renkus-Heinz SETUP-IC) is
needed to connect and convert your computer's USB output to RS422. The USB to RS422 converter/adapter terminates in a 9-pin DB-9
connector. Each module provides a DB-9 connector plus a “looping’ 5-pin Phoenix connector. Note that if you are using another USB to
RS422 converter/adapter, it must have a communications speed of at least 9600 baud.
3. The system allows up to 8 columns (16 modules) to be controlled from a single COM Port.
RS422 Contol Cable
Audio Cable
From Audio Source
IC Live Users Manual, ICL-F & ICL-F-DUAL