background image

USING CANVAS

1. To open the Canvas program, click on the Canvas Icon the installer program placed on your desktop. The screen shown below will open.

Notice that you have several options; one is to select the column array you want to control through use of the drop down arrow. You also

have a choice of initializing the column array to the default setting or of retrieving the column array’s previous settings. We recommend that

you use ”Retrieve current settings from module” since several of the parameters were preset by us before shipment.

Clicking on OK opens the following window.

Notice the blank window in the lower right corner of the screen. You may have to use the scroll bars to view it in its entirety.

IC Live Users Manual, ICL-F & ICL-F-DUAL

29

All manuals and user guides at all-guides.com

Summary of Contents for Iconyx IC Live ILC-F-DUAL

Page 1: ...C Live Users Manual Models ICL F ICL F DUAL Owners Manual USERS MANUAL Assembly Installation Instructions ICL F ICL F DUAL IC Live All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...r The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on it 6 Clean only with dry cloth 7 Do not block any ventilation openings...

Page 3: ...2 15 Canvas 29 Installation 32 Cabling Required 32 Power 32 Hardware Connections 33 Dimensions 34 Audio Digital Control 32 Installation 32 Wall Mounting 36 Suspended Flying 37 Servicing 37 Trouble Sho...

Page 4: ...UAL is included in the cartons If you ordered a HK ICL series mounting hinge kit with your ICL F array the hinge hardware will be packed with the other hardware If you are not constructing a dual arra...

Page 5: ...e top of both modules To remove the top remove the eight machine screws from each side of the cabinet and lift the top and its mounting brackets out of the cabinet as shown The next step is to install...

Page 6: ...ors are fully seated You should hear a click when they seat If necessary use a flashlight to check because if the connectors are not seated properly you may have to disas semble the column again in or...

Page 7: ...loudspeakers are installed 2 Remove the access plate and locate the Address switches Each 8 channel module will have an access plate Notice that there are 8 orange on off Dip switches The switches are...

Page 8: ...typical system layout is shown below Notes 1 The audio cable is a conventional twisted pair shielded audio cable It terminates in a 3 pin Phoenix connector and loops from column to column looping Phoe...

Page 9: ...ncing levels during final commissioning Inserting the Iconyx Software CD into the computer s CD ROM drive will open the splash menu screen shown below here INSTALLING THE USB TO RS422 ADAPTER DRIVERS...

Page 10: ...s Logo testing with the fol lowing message Click on Continue Anyway Windows will finish the driver installation Click on Finish when prompt ed 4 Windows will now find another hardware device which is...

Page 11: ...driver you will be prompted to install it click on Next After Windows finishes installing the driver click Finish when prompted 4 Windows will now find another hardware device which is the Serial Port...

Page 12: ...Device Manager icon and look for USB to Serial Cable with a yellow exclamation mark You may find it under Universal Serial Bus Controllers Other Devices or Unknown Devices Double click the USB to Seri...

Page 13: ...eeding You may down load NETFramework 2 0 from that same location on our website as the BeamWare 2 download or from Microsoft s download site http microsoft com downloads Click on Next to start the in...

Page 14: ...Select the Icon Option you wish to use and then click on Next to contin ue D Click on Install to begin the instal lation E Click on Done to complete the installation Notice that the installer will ha...

Page 15: ...ay to do this is to go to the Project pull down menu select Layout Presets and open the Preset folder Then choose one of the example floor plans For our purposes we ll use the floor plan of the Church...

Page 16: ...ntal coverage Position the array by grabbing the yellow icon with your mouse cursor and moving it Clicking on the red box which identifies the aiming point allow you to change the aiming point A third...

Page 17: ...array but didn t select one of them a Select Array prompt will list the arrays you inserted into the project under Layout and ask you to select one of them Note that you can also enter the Array Prope...

Page 18: ...hysical dimensions of the area s you want to cover so the next logical step is to set up the audience area s using the Audience Area section on the right side of the screen To simplify this step BeamW...

Page 19: ...op down menu One of the unique features of Iconyx steerable arrays is the ability to generate either single or multiple lobes We ll be discussing multiple lobes later in this tutorial so for now accep...

Page 20: ...dium Resolution You also have the opportunity to choose the simulation s Bandwidth its Center Frequency and its Weighting The Frequency section lets you select center frequencies from 100 to 10 000 Hz...

Page 21: ...um of 8 lobes It s up to four on the IC 8L For now select 2 to add a second beam to the graphic At first glance it may appear that nothing happened since the program placed the second beam on top of t...

Page 22: ...can override this warning if you want and the program will still attempt to properly focus all the beams You may however want to try moving the array up or down to see if you can find a better locatio...

Page 23: ...g was narrowed to 25o to obtain a longer throw The next graphic shows an even larger room one with a 125 foot throw Note that the opening angle was reduced to 20o Still the level is starting to fall o...

Page 24: ...ws you to Export save the BeamWare 2 Setup as a rhs Setup file that can easily be imported into EASE and EASE JR It s a simple thing to do just open the EASE Iconyx DLL file into your EASE project in...

Page 25: ...modules In BeamWare 2 these relationships are stored in the following manner every Column has a unique ID ICID number and every Array has a unique ID Array ID number When a column is assigned to an a...

Page 26: ...Note that you may have to adjust the Columns in Network section of the window to see the entire listing The next step is to scan the network for Columns Arrays Hardware that can be linked to the Arra...

Page 27: ...siest way to assign one of the Columns to an Array is to grab it using the cursor and left mouse button and drag it to one of the Column icons Notice that the color of the Column icon changes when a C...

Page 28: ...xplore the two setup options we ignored earlier see page 35 The Scan for new Arrays on network option is similar to the Scan for Columns on network option except that it also identifies previously est...

Page 29: ...f initializing the column array to the default setting or of retrieving the column array s previous settings We recommend that you use Retrieve current settings from module since several of the parame...

Page 30: ...n inserts a high pass filter into the signal chain and allows you to dial in any low frequency roll off you desire It was preset to 100 Hz with a 24 dB per octave slope Please don t attempt to set it...

Page 31: ...Signal Generator but ton will bring up the following screen which allows you to choose the signal s frequency and distribute the signal to the column array Please note that changes are not saved in th...

Page 32: ...lude a power on off switch and you will have to make sure an external power on off switch is provided Each module however does include a self restoring circuit breaker as protection against damage in...

Page 33: ...Recommended RS422 data wire type CAT5E wire is acceptable or for shielded type Belden 9729 has been tested by Renkus Heinz up to 800 meters When using long wire lengths a 120 Ohm terminating resistor...

Page 34: ...s See Page 7 Audio Input Looping Connectors Push To Reset Circuit Breaker Power Connector Universal 100 to 240 Volts 50 60 Hz Signal Limiting Status LEDs See Page 7 Hardware Inputs 34 IC Live Users Ma...

Page 35: ...Dimensions 44 1 4 112 5 cm 47 119 5 cm 95 241 5 cm 44 1 4 112 5 cm 8 20 cm 8 20 cm 7 17 8 cm 48 122 cm 35 IC Live Users Manual ICL F ICL F DUAL All manuals and user guides at all guides com...

Page 36: ...he Fault Monitor to the network and press OK The Monitoring tab in the Options folder allows you to adjust the scan interval time from 5 seconds to 300 sec onds Use the Up and Down arrows to select wh...

Page 37: ...h amplifier module and reports any failures such as loss of power It also checks the amplifiers operating temperature and reports any over temperature find ings If a fault is detected the nature of th...

Page 38: ...ng away from the wall ICL F columns will have two hinge sec tions ICL F DUAL columns will have three hinge sections The female hinges should be attached to the column and the male hinges to the wall T...

Page 39: ...erly made Note The ICL F audio inputs comply with AES Standard 48 2005 on interconnecting grounding and shielding i e pin 1 is connected to chassis NOISE Most noise problems are the result of improper...

Page 40: ...rements 8 Exporting to EASE 24 F Fault Monitoring 36 37 Filters 30 H Hinges 36 I Installation Columns 38 Software 8 to 14 Level control 31 N NetFramework 8 13 Network Setup 25 Scanning 26 27 P Paramet...

Page 41: ...when stacked Five 6 5 inch cone transducers with neodymium magnets Three 1 inch HF titanium nitride compression drivers 8 per module ICL F 48 H x 8 W x 7 D 121 5 cm x 20 cm x 17 8 cm ICL F DUAL 95 H...

Page 42: ...19201 Cook Street Foothill Ranch CA USA Phone 1 949 588 9997 Fax 1 949 588 9514 sales renkus heinz com www renkus heinz com RH 657 Rev B March 2010 All manuals and user guides at all guides com...

Reviews: